Specifications – Enviro C-10914 User Manual
Page 5
5
Specifications
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
D
IMENSIONS
:
16
5
/
8
"
(42.2cm)
25 3⁄4"
(65.3cm)
25 3⁄4"
(65.4cm)
27"
(68.6cm)
25 3⁄4"
(65.3cm)
17
1
/
8
"
(43.5cm)
15 3⁄4"
(40.0cm)
27"
(68.5cm)
15
1
/
8
"
(39.0cm)
Floor to center of flue
REAR VENT
231⁄2” (59.7 cm)
C
LEARANCES
TO
C
OMBUSTIBLES
:
A. Sidewall to unit
11 inches (27.9 cm)
B. Backwall to unit
2.5 inches (6.35 cm)
C. Corner to unit
2.5 inches (6.35 cm)
D. Ceiling
60 inches above floor (152.4 cm)
E. Floor
(hard wood and linoleum) 0 inches
Note: When installing on a carpeted surfaces a non-
combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width
48 inches (121.9 cm)
Height
60 inches (152.4 cm)
Depth (max)
24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
Figure 1: Westport Exterior Dimensions.
�
�
�����
���� ����
��
�
�
�
��
�
�
�
��
��
�
�������� ����
�
�
��
��
�
�
�
��
�
Figure 2: Clearances to combustibles.