Initial installation – Enviro C-10914 User Manual
Page 24
3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-
crimped end on the unit
4. Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit
the structure.
5. Project a level line from the center point of the elbow. Using this center point, scribe a 10” (25.4 cm)
hole or square on the wall. Cut the hole out on both the interior and exterior wall surface.
6. Frame the hole as shown in Figure 17.
����
�������
Figure 30: Cut away of
spacers on Flex Pipe.
Figure 31: Top view of spacers on
Flex Pipe.
Initial Installation
QUALIFIED INSTALLERS ONLY
7. Install the wall thimble and secure the thimble to the inner wall surface.
8. With the appliance still in place install the 24” (61 cm) horizontal section on
the elbow and let this section of pipe protrude through the exterior surface.
Mark the pipe so that when it is cut it will be flush with the exterior wall.
9. Dismantle the outer pipe sections.
10. Install the 4” (10 cm) adaptor into the exhaust outlet on the unit. Apply a
bead of high temperature silicone.
11. Stretch the liner out. Attach the flexible liner to the vent termination cap by
placing a small bead of high temperature silicone on the vent termination
and slide the flex liner onto the vent terminal and secure with three (3)
sheet metal screws evenly spaced.
12. Dress the flex liner through the wall thimble and attach the vent terminal
to the outside of the house using four (4) wood screws provided. The
use of non-hardening mastic should be used around the vent to ensure a
watertight seal.
13. Install two (2) wire spacer around the flex pipe. Slide the horizontal section
of pipe over the flexible liner. Ensure the wire spacers are positioned at
either end of the pipe (refer to Figure 30 and 31).
16. Slide the 90° elbow over the flex pipe. Do not slip the
outer sections of pipe together, you will require some
movement in these pipe section in order to secure the
flex pipe to the flue outlet on the appliance.
17. Stretch the flex liner to a length long enough to ensure the flex
liner can be easily connected to the flue outlet of the appliance.
18. Install the remaining wire spacers over the flexible liner and
install the vertical section of pipe. Ensure the wire spacers are
positioned at either end of the pipe (refer to Figure 30 and 31).
19. Place a bead of high temperature silicone on the flue pipe and
slide the flex liner over the collar, secure the flex liner with three
(3) sheet metal screws evenly spaced.
14. Install the horizontal section of pipe through the wall thimble, ensure that this portion of pipe slides
onto the vent termination cap.
15. Slide the inside finished collar over the horizontal section of pipe and secure to wall using the screw
provided.
24