beautypg.com

Initial installation – Enviro Westport C-10381 User Manual

Page 13

background image

Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can

result in carbon monoxide (CO) poisoning and possible death.

P

RePaRation

F

oR

i

nstaLLation

:

• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is

found, please report it to both the carrier and your dealer as soon as possible.

• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the

integrity of the building; e.g. cutting a wall or ceiling joist.

• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat

circulation and comfort.

• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8

m) of the stove.

• The flow of combustion and ventilation air must not be obstructed.

c

LeaRances

to

c

ombustibLes

:

A. Sidewall to unit

11 inches (27.9 cm)

B. Backwall to unit

2.5 inches (6.35 cm)

C. Corner to unit

2.5 inches (6.35 cm)

D. Ceiling

60 inches above floor (152.4 cm)

E. Floor

(hard wood and linoleum) 0 inches

Note: When installing on a carpeted surfaces a non-

combustible hearth pad must be used.
Minimum Alcove Dimensions:

Width

48 inches (121.9 cm)

Height

60 inches (152.4 cm)

Depth (max)

24 inches (60.96 cm)

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

P

Lanning

y

ouR

i

nstaLLation

:

When planning your installation, it will be necessary to select the proper length of vent pipe for your

particular requirements. It is important to note when passing through a wall, the maximum allowable

wall thickness is 10 inches (25.4 cm), 1½ inches (3.8 cm) clearance to combustibles must be maintained.

Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine

the length of vent pipe required for vertical installations, measure the distance from the appliance flue

outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow

for sufficient vent height above the roof line. For two story applications, a fire stop is required at each

floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the

venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.

Refer to i

nitial

i

nStallation

- v

ent

c

onfiGuration

and

r

eStrictor

S

ettinGS

for venting parameters.

B

A

Front

Back wall

Si

d

e

w

al

l

C

C

Fr

on

t

Adjacent wall

A

d

ja

ce

n

t

w

al

l

Figure 14: Clearances to combustibles.

This manual is related to the following products: