Initial installation – Enviro Westport C-10381 User Manual
Page 13
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
P
RePaRation
F
oR
i
nstaLLation
:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8
m) of the stove.
• The flow of combustion and ventilation air must not be obstructed.
c
LeaRances
to
c
ombustibLes
:
A. Sidewall to unit
11 inches (27.9 cm)
B. Backwall to unit
2.5 inches (6.35 cm)
C. Corner to unit
2.5 inches (6.35 cm)
D. Ceiling
60 inches above floor (152.4 cm)
E. Floor
(hard wood and linoleum) 0 inches
Note: When installing on a carpeted surfaces a non-
combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width
48 inches (121.9 cm)
Height
60 inches (152.4 cm)
Depth (max)
24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
P
Lanning
y
ouR
i
nstaLLation
:
When planning your installation, it will be necessary to select the proper length of vent pipe for your
particular requirements. It is important to note when passing through a wall, the maximum allowable
wall thickness is 10 inches (25.4 cm), 1½ inches (3.8 cm) clearance to combustibles must be maintained.
Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine
the length of vent pipe required for vertical installations, measure the distance from the appliance flue
outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow
for sufficient vent height above the roof line. For two story applications, a fire stop is required at each
floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the
venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.
Refer to i
nitial
i
nStallation
- v
ent
c
onfiGuration
and
r
eStrictor
S
ettinGS
for venting parameters.
B
A
Front
Back wall
Si
d
e
w
al
l
C
C
Fr
on
t
Adjacent wall
A
d
ja
ce
n
t
w
al
l
Figure 14: Clearances to combustibles.