OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
1. To open the dust cup (container),
push dust cup release button and pull
out the dust cup. Verify that the HEPA
dust cup filter with the debris screen
is inside, then re-attach the dust cup
(container) to the hand vacuum.
(Fig. 1)
3. To attach the crevice tool,
turbo brush, dusting brush
accessory to the hand vacuum,
push attachment into the suction
hole. (Fig. 3)
4. To use the flexible hose, push the
smaller end of the hose into the
suction hole, then attach the
desired accessory to the other end
of the flexible hose. (Fig. 4)
2. To use the hand
vacuum with the
shoulder strap,
attach it to the unit
as shown in Fig. 2.
Fig. 2
Fig. 1
Fig. 4
Fig. 3
Warning:
Always unplug from
electrical outlet before opening the
dust cup (container).
Note
: HEPA dust cup filter must be
used when operating the hand
vacuum.
How To Operate Your Hand Vac
1. Hold the hand vacuum firmly in your
hand by the handle.
2. Push the On/Off switch to “On” position.
3. Start vacuuming.
How To Operate Your Hand
Vacuum
Fig. 16
CAUTION
: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
6. Hold the filter from the frame and
vigorously
“TapClean” the
HEPA Dust Cup
Filter on a hard
surface until no more
dust is observed
falling out from
between the pleats of
the filter. (Fig. 16) Ensure that you do
not damage the pleated filter material
during cleaning. Also note that
discoloration occurs during use. This is
normal and does NOT affect the filter’s
performance.
7. To replace the HEPA filter, grasp the
HEPA filter in one hand and the
HEPA filter frame flange in the other
and pull apart. Fit the new HEPA filter
into the frame flange.
8. Reassemble the debris screen to the
HEPA filter cartridge and replace into
dust cup (container). Ensure that the
filter assembly is completely seated
inside the dust cup (container).
9. Attach the dust cup (container) to the
hand vacuum.
Important:
Do NOT use the HEPA filter
cartridge without the debris screen in
place.
Warning:
It is very important to ensure
that the fine dust which adheres to the
filter media is completely removed. This
fine dust powder is left on the filter will
severely reduce the suction performance
of your vacuum. TapClean every time the
dust cup is emptied.
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Dust Cup Filter
is properly
"TapCleaned”
after each use
and suction
does not return
to 100%, then
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until no
more dust can be removed, then
rinsed under the faucet and allowed to
dry for 24 hours before refitting into
the vacuum. (Fig. A) Wash once a
month or when suction appears
reduced.
Fig. A
Wash once a
month or when
suction
appears
reduced.
Warning:
Allow 24
hours for drying before
replacing in unit.
IMPORTANT:
This unit is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
• Push the On/Off button once.
• Disconnect the plug from the
power source.
• Check the source of overheating
problem. (i.e. clogged hose or
filter)
• If clogged hose or filter is found,
unclog the hose and replace the
filters.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
• If the vacuum still does not start,
contact customer service at
1 (800) 798-7398.
5. Rinse the debris screen under the
faucet until clean. Allow to air dry or
dry with a clean dish towel. Do NOT
wash in dishwasher.
Caution:
The hand vacuum is a very
powerful unit. Make sure that you hold
it firmly, otherwise it can slip out of your
hand and cause injury.
Using the Unit With Air Driven
Turbo Brush and Hose
1. Attach one end of the hose to the
hand vacuum.
2. Attach the air driven turbo brush to the
other end of the hose.
3. Attach the shoulder strap to the
vacuum and hang it from your shoulder.
4. You can now proceed to vacuum with
your air driven turbo brush.
NOTE: The air driven turbo brush can also
be attached directly onto the unit, or the
extension tubes. To ensure peak
performance from the air driven turbo
brush:
1. Empty the dust cup frequently.
2. “TapClean” the HEPA dust cup filter
every time dust cup is emptied.
3. Ensure that the rotating brush is kept
free of hair and string which may
accumulate and decrease brush
performance.
4. Keep air driven turbo brush turbine
free of dirt and foreign matter.
Cleaning Air Driven Turbo Brush
Turbine
Wheel
Tilt
Upwards
Locking
Latch
Fig. 5
From time to time, the turbine of your turbo
brush will require cleaning. To do this:
1. Remove the turbo brush from the hose
or unit.
2. Turn turbo brush over and open the
hinged cover to access the turbine
wheel. (Fig. 5)
3. There may be some dust, lint, hair, etc
on the turbine wheel. Remove as much
of this as possible.
4. You may also use the unit’s hose to
remove any additional debris from the
turbine.
6