beautypg.com

Operating instructions – Euro-Pro RETRACTORTM TOTAL SYSTEM VAC EP187H User Manual

Page 5

background image

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

1. To open the dust cup (container),

push dust cup release button and pull

out the dust cup. Verify that the HEPA

dust cup filter with the debris screen

is inside, then re-attach the dust cup

(container) to the hand vacuum.

(Fig. 1)

3. To attach the crevice tool,

turbo brush, dusting brush

accessory to the hand vacuum,

push attachment into the suction

hole. (Fig. 3)

4. To use the flexible hose, push the

smaller end of the hose into the

suction hole, then attach the

desired accessory to the other end

of the flexible hose. (Fig. 4)

2. To use the hand

vacuum with the

shoulder strap,

attach it to the unit

as shown in Fig. 2.

Fig. 2

Fig. 1

Fig. 4

Fig. 3

Warning:

Always unplug from

electrical outlet before opening the

dust cup (container).

Note

: HEPA dust cup filter must be

used when operating the hand

vacuum.

How To Operate Your Hand Vac

1. Hold the hand vacuum firmly in your

hand by the handle.

2. Push the On/Off switch to “On” position.

3. Start vacuuming.

How To Operate Your Hand
Vacuum

Fig. 16

CAUTION

: The suction hole must be

open, free of any obstructions at all

times. Otherwise, the motor will overheat

and could become damaged.

6. Hold the filter from the frame and

vigorously

“TapClean” the

HEPA Dust Cup

Filter on a hard

surface until no more

dust is observed

falling out from

between the pleats of

the filter. (Fig. 16) Ensure that you do

not damage the pleated filter material

during cleaning. Also note that

discoloration occurs during use. This is

normal and does NOT affect the filter’s

performance.

7. To replace the HEPA filter, grasp the

HEPA filter in one hand and the

HEPA filter frame flange in the other

and pull apart. Fit the new HEPA filter

into the frame flange.

8. Reassemble the debris screen to the

HEPA filter cartridge and replace into

dust cup (container). Ensure that the

filter assembly is completely seated

inside the dust cup (container).

9. Attach the dust cup (container) to the

hand vacuum.

Important:

Do NOT use the HEPA filter

cartridge without the debris screen in

place.

Warning:

It is very important to ensure

that the fine dust which adheres to the

filter media is completely removed. This

fine dust powder is left on the filter will

severely reduce the suction performance

of your vacuum. TapClean every time the

dust cup is emptied.

PLEASE NOTE: The white pleated

filter material in the HEPA Dust Cup

Filter will discolor over time -This is

NORMAL and will NOT affect the

performance of the filter. If the HEPA

Dust Cup Filter

is properly

"TapCleaned”

after each use

and suction

does not return

to 100%, then

we suggest that

the HEPA filter

be “TapCleaned”

vigorously until no

more dust can be removed, then

rinsed under the faucet and allowed to

dry for 24 hours before refitting into

the vacuum. (Fig. A) Wash once a

month or when suction appears

reduced.

Fig. A

Wash once a

month or when

suction

appears

reduced.

Warning:

Allow 24

hours for drying before
replacing in unit.

IMPORTANT:

This unit is equipped

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

automatically turn the unit off. Should

this occur:

• Push the On/Off button once.

• Disconnect the plug from the

power source.

• Check the source of overheating

problem. (i.e. clogged hose or

filter)

• If clogged hose or filter is found,

unclog the hose and replace the

filters.

• Wait at least 45 minutes before

attempting to reuse the vacuum.

• After unit has cooled down for

45 minutes, plug in the cleaner

and push the On/Off button. The

vacuum should start again.

• If the vacuum still does not start,

contact customer service at

1 (800) 798-7398.

5. Rinse the debris screen under the

faucet until clean. Allow to air dry or

dry with a clean dish towel. Do NOT

wash in dishwasher.

Caution:

The hand vacuum is a very

powerful unit. Make sure that you hold

it firmly, otherwise it can slip out of your

hand and cause injury.

Using the Unit With Air Driven
Turbo Brush and Hose

1. Attach one end of the hose to the

hand vacuum.

2. Attach the air driven turbo brush to the

other end of the hose.

3. Attach the shoulder strap to the

vacuum and hang it from your shoulder.

4. You can now proceed to vacuum with

your air driven turbo brush.

NOTE: The air driven turbo brush can also

be attached directly onto the unit, or the

extension tubes. To ensure peak

performance from the air driven turbo

brush:

1. Empty the dust cup frequently.

2. “TapClean” the HEPA dust cup filter

every time dust cup is emptied.

3. Ensure that the rotating brush is kept

free of hair and string which may

accumulate and decrease brush

performance.

4. Keep air driven turbo brush turbine

free of dirt and foreign matter.

Cleaning Air Driven Turbo Brush

Turbine

Wheel

Tilt

Upwards

Locking

Latch

Fig. 5

From time to time, the turbine of your turbo

brush will require cleaning. To do this:

1. Remove the turbo brush from the hose

or unit.

2. Turn turbo brush over and open the

hinged cover to access the turbine

wheel. (Fig. 5)

3. There may be some dust, lint, hair, etc

on the turbine wheel. Remove as much

of this as possible.

4. You may also use the unit’s hose to

remove any additional debris from the

turbine.

6