beautypg.com

Specifications, Air control specifications – Enviro Venice User Manual

Page 10

background image

S

PECIFICATIONS

:

Table 1: 1200-V & 1700-V General Information.

Model

1200 Insert

1700 Insert

Width x Depth

273⁄4” x 211⁄2”

(705 mm x 546 mm)

273⁄4” x 26”

(705 mm x 660 mm)

Height of body

19

1

/

16

” (484 mm) or 19

9

/

16

” (497 mm)

Fire box size
(depth x width x height)

16.1” x 18.25” x 11.15”

(409 mm x 464 mm x 283 mm)

20.65” x 18.25” x 11.95”

(525 mm x 464 mm x 304 mm)

Capacity

1.85 feet3

(0.0526 meter3)

2.5 feet3 (0.0708 meter3)

* Approximate heating area

800 - 1,500 feet2

(74.3 - 139.4 meter2)

1,000 - 2,200 feet2

(92.9 - 205.4 meter2)

**E.P.A. output rating

11,479 to 34,196 BTU/hour

(3,361 to 10,013 watt)

9,425 to 31,780 BTU/hour

(2,760 to 9,306 watt)

*Duration on low burn

6 -10 hours

8 - 12 hours

Weight with packaging

335 lb (151.95 Kg)

390 lb (176.90 Kg)

E.P.A. Emissions

3.3 grams/hour

(0.116 oz/hour)

4.48 grams/hour

(0.158 oz/hour)

Surround Panels

Standard (width x height)

461⁄8” x 28” (1171 mm x 711 mm)

Oversized (width x height)

461⁄8” x 331⁄8” (1171 mm x 843 mm)

Rating Label Location

Side of Unit; Behind Right Shroud

10

Specifications

A

IR

C

ONTROL

:

The air wash and pilot air (control the amount of air to the fire) are controlled by the rod located on the

right side of the unit. To increase your air, pull the rod out and to decrease, push the rod in. All the units

have a secondary air that flows through the tubes at the top of the firebox, just below the baffles.
Pull this control all the way out when first starting the

stove. Once the fire has been established you may

adjust this control to set the burn rate of the fire. If

this damper is closed at first start-up, the fire will burn

very slowly and could soot the appliance.
When shutting down the stove, fully open the air

control. This allows the chimney temperatures to

remain as high as possible for as long as possible. Cold

chimney temperatures create creosote.

Increase air - pull rod out

Decrease air - push rod in

Figure 3: Air Control Rod.

This manual is related to the following products: