beautypg.com

Operation pe-225 – Echo PE-225 User Manual

Page 16

background image

16

X7722272307

© 3/2013 ECHO Inc.

OPERATION

PE-225

Fuel tanks/cans may be under pressure. Always loosen fuel caps slowly allowing pressure to

equalize.

NEVER refuel a unit when the engine is HOT or RUNNING!

DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks outdoors over bare ground.

DO NOT overfill fuel tank. Wipe up spills immediately.

Securely tighten fuel tank cap and close fuel container after refueling.

Inspect for fuel leakage. If fuel leakage is found, do not start or operate unit until leakage is

repaired.

Move at least 3m (10 ft.) from refueling location before starting the engine.

Mixing Instructions
1. Fill an approved fuel container with half of the required

amount of gasoline.

2. Add the proper amount of 2-stroke oil to gasoline.
3. Close container and shake to mix oil with gasoline.
4. Add remaining gasoline, close fuel container, and remix.

Spilled fuel is a leading cause of hydrocarbon emissions. Some
states may require the use of automatic fuel shut-off containers
to reduce fuel spillage.

After use

• DO NOT store a unit with fuel in its tank. Leaks can occur. Return unused fuel to an approved fuel storage

container.

Storage - Fuel storage laws vary by locality. Contact your local government for the laws affecting your area.
As a precaution, store fuel in an approved, airtight container. Store in a well-ventilated, unoccupied building,
away from sparks and flames.

Stored fuel ages. Do not mix more fuel than you expect to use in thirty (30) days, ninety (90) days when a
fuel stabilizer is added.

Stored two-stroke fuel may separate. ALWAYS shake fuel container thoroughly before each use.