Run engine at one-third throttle, with brake
disengaged, move levers in and raise off seat (but
do not get off of machine) engine must initiate
shutdown
after 1/2 second has elapsed.

Again, run engine at one-third throttle, brake
engaged, and move left motion control lever
in
- engine must initiate shutdown after 1/2
second has elapsed.

Repeat again moving the right lever in, then
moving both levers in - engine must initiate
shutdown
after 1/2 second has elapsed whether
operator is on seat or not.

Note: If machine does not pass any of these tests,
do not operate. Contact your authorized EXMARK
SERVICE DEALER.

Important: It is essential that operator safety
mechanisms be connected and in proper
operating condition prior to use for mowing.

Check Rollover Protections
Systems (Roll Bar) Knobs

Service Interval: Before each use or daily

Check that both the mounting hardware and the
knobs are in good working condition. Make sure the
knobs are fully engaged with the ROPS in the raised
position. The upper hoop of the roll bar may need
to be pushed forward or pulled rearward to get both
knobs fully engaged.

Figure 22

1.

Engaged

2.

Partially engaged — Do
Not operate with ROPS
in this condition.

Check Seat Belt

Service Interval: Before each use or daily

Visually inspect seat belt for wear, cuts, and proper
operation of retractor and buckle. Replace before
operating if damaged.

Check for Loose Hardware

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Visually inspect machine for any loose hardware

or any other possible problem. Tighten hardware
or correct the problem before operating.

Service Air Cleaner

Service Interval: Every 250 hours—Replace

the primary air cleaner
element — check
secondary air cleaner
element; replace if dirty.
(May need more often
under severe conditions.
See the Engine Owner’s
Manual for additional
information.)

Every 500 hours—Replace
the secondary air cleaner
element (May need more
often under severe
conditions. See the
Engine Owner’s Manual
for additional information.)

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. See the Engine Owner’s Manual for maintenance

instructions.

Change Engine Oil

Service Interval: After the first 5 hours

Every 100 hours/Yearly
(whichever comes first)
(May need more often
under severe conditions.)

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Drain oil while engine is warm from operation.