OPERATING INSTRUCTIONS

PRECAUTIONARY MEASURES

Cleaning & Changing the Hepa-
Type Filter

CAUTION

: The suction hole must be

open, free of any obstructions at all

times. Otherwise, the motor will

overheat and could become damaged.

Warning:

Always empty the dust cup

container and clean the HEPA-Type

filter before each use and during

prolonged usage.

Never over fill the dust cup (container) -

remove dirt and clean the HEPA-Type

filter when dirt in dust cup is at or below

the "MAX" level during prolonged usage

or risk motor damage.

If you wash the HEPA-Type filter,

make sure that it is completely air

dry before inserting back in the

vacuum.

Please Note: The HEPA-Type filter is

washable. It should, however, be

replaced every three (3) to six (6)

months, depending on usage to ensure

peak performance of your vacuum.

PLEASE NOTE:

The white pleated

filter material in the HEPA-Type dust

cup filter will discolor over time -This

is NORMAL and will NOT affect the

performance of the filter. If the HEPA-

Type dust cup

filter is properly

"TapCleaned”

after each use

and suction

does not return

to 100%, then

we suggest that

the HEPA-Type

filter be

“TapCleaned”

vigorously until no

more dust can be removed, then

rinsed under the faucet and allowed to

air dry for 24 hours before refitting into

the vacuum. (Fig. A) Wash once a

month or when suction appears

reduced.
Re-Installing Dust Cup (Container)

1. Ensure that small air intake vent

on the dust cup is aligned with the

opening on the main unit. (Fig. 12)

2. Slide the dust cup container into

place and lower the dust cup

retainer handle.

3. Push retainer handle until you hear

it lock into place. (Fig. 13)

Fig. A

Wash once a

month or when

suction

appears

reduced.

Warning:

Allow 24

hours for air drying
before replacing in unit.

Motor Thermostat

Important:

This unit is equipped

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

automatically turn the unit off. Should

this occur:

Push the On/Off button once.

Disconnect the plug from the

power source.

Check the source of overheating

problem. (i.e. clogged hose or

filter)

If clogged hose or filter is found,

unclog the hose and replace the

filters.

Wait at least 45 minutes before

attempting to reuse the vacuum.

After unit has cooled down for

45 minutes, plug in the cleaner

and push the On/Off button. The

vacuum should start again.

If the vacuum still does not start,

contact customer service at

1 (800) 798-7398.

Fig. 13

Air Intake

Vent

Fig. 12

IMPORTANT:

If the suction opening in the unit or the hose is BLOCKED, switch off

the vacuum cleaner and remove the blocking substance before you

start the unit again.

1. Do not operate the vacuum cleaner

too close to heaters or radiators.

4. When pulling out the power plug

from the wall outlet, pull the plug not

the power cord.

5. Do not pick up anything that is

burning or smoking such as
cigarettes, matches or hot ashes.

2. Before inserting the power plug into

the wall outlet, make sure that your

hands are dry.

3. Before you start vacuuming, make

sure to remove large or sharp objects

that might cause damage to the unit.

6. Do not vacuum any liquids.

7. Do not use without dust cup

(container) or HEPA-Type filter in
place.

Note:

This vacuum cleaner is equipped

with a plug and power cord that retract

automatically. If the cord or plug get

damaged, it must be replaced by a

qualified technician.

Warning:

Hold the plug when

rewinding the cord. Do not allow the

cord to whip when rewinding.