beautypg.com

Emerson Process Management DVS205 User Manual

Dvs205 dual-variable sensor, Technical specifications

background image

DVS205

April

2011

Technical Specifications

DVS205 Dual-Variable Sensor

The DVS205 Dual-Variable Sensor (DVS205)
provides static pressure and differential pressure
inputs to a FloBoss™ 103, FloBoss 107E, or FloBoss
500-Series Flow Manager. The DVS205
communicates via a serial format with the FloBoss.

Remote Automation Solutions

Website: www.EmersonProcess.com/Remote

D301569

X012

Variables

Functionally, the DVS205 is a digital transmitter that
measures two flow-related variables simultaneously:
differential pressure and static pressure. These
variables are continuously available to the FloBoss
unit that polls the DVS205.

Transducer and Electronics

The DVS205 contains a transducer and an
electronics circuit. The transducer uses capacitance-
cell technology to sense differential pressure and
piezoresistive technology to sense the static
(absolute or gauge) pressure.

The transducer electronics convert the pressure
variables directly into a digital format, allowing

accurate correction and compensation. A
microprocessor linearizes and corrects the raw
pressure signals (from the sensor) using
characterization data stored in non-volatile memory.

The electronics also allow the DVS205 to
communicate with a FloBoss using a Serial
Peripheral Interface (SPI).

Accuracy

Two versions of the DVS205 are available:
ƒ 205P with reference accuracy of 0.075% of the

full span.

ƒ 205E with reference accuracy of 0.10% of the

full span.

Mounting

The DVS205 is factory installed on a FloBoss™ 103,
FloBoss 107E, or FloBoss 500-Series Flow Manager
to comply with agency requirements. Attached to the
bottom of the sensor body is a Coplanar™ flange.
This flange allows the DVS205 to mount on an
integral orifice assembly or manifold valve.



Coupling

Sensor Body

Coplanar
Flange

W8826-A

DVS205 Dual-Variable Sensor

Table of contents