beautypg.com

Al390kcl-339011 p11 – Kichler 339011 User Manual

Page 12

background image

11

14. SPECIFICATIONS

1.92'

7.17

kgs

11.48

kgs

0.49

0.35

0.20

59.0

28.0

9.50

160

113

62

4500

3196

1602

76.28

114.13

168.63

RPM

CFM

CFM/W

N.W.

G.W.

C.F.

120

120

120

Fan Size

52"

Speed Volts Amps Watts

High

Medium

Low

These are approximate measures. They do not include Amps and Wattage used by the light kit.

13. TROUBLESHOOTING

Problem

Fan will not start.

Fan sounds noisy.

Fan wobble.

Solution

1. Check that all fuses or circuit breakers are installed or in the ON position.
2. Check all electrical connections to insure proper contact.

CAUTION: Make

sure the main power is OFF when checking any electrical connection.

1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade bracket to the motor hub is

tight.

3. Make sure wire nut connections are not rubbing against each other or the

interior wall of the switch housing.

CAUTION: Make sure main power is off.

4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan

disappear during this time.

5. If using an optional light kit, make sure the screws securing the glassware

are tight. Make sure the light bulbs are not touching any other component.

6. Some fan motors are sensitive to signals from solid-state variable speed

controls. If you have installed this type of control, choose and install another
type of control.

7. Make sure the upper canopy is a short distance from the ceiling. It should not

touch the ceiling.

1. Check that all blade and blade arm screws are secure.
2. Most fan wobbling problems are caused when blade levels are unequal.

Check this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance. Rotate the fan until the next blade is
positioned for measurement. Repeat for each blade. The distance deviation
should be equal within 1/8".

3. Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable.
4. If the blade wobble is still noticeable, interchanging two adjacent (side by

side) blades can redistribute the weight and possibly result in smoother
operation.

WARNING: TO REDUCE THE RISK OF PERSONAL INJURY AND TO INUSRE THE
PROPER OPERATION OF YOUR CEILING FAN. NEVER ATTACH THE BLADE
ASSEMBLIES UNTIL THE CEILING FAN HAS BEEN MOUNTING ON THE CEILING.
DO NOT BEND THE BLADE ARMS WHILE INSTALLING, BALANCING OR
CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN
ROTATING FAN BLADES.