beautypg.com

Hendrick – Kichler 300114 User Manual

Page 7

background image

6

Hendrick

TM

Fig. 11

Fig. 12

Fig. 13

7. MAKE THE ELECTRIC CONNECTIONS

WARNING: To avoid possible electrical shock,
be sure electricity is turned off at the main fuse
box before wiring.

NOTE: The CoolTouch

TM

control system is

equipped with 16 code combinations to prevent
possible interference from or to other remote
units. The frequency switches on your receiver
and transmitter have been preset at the factory.
Please recheck to make sure the switches on
transmitter and receiver are set to the same
position, any combination of settings will
operate the fan as long as the transmitter and
receiver are set to the same position. (Fig. 12)

Step 1. (Fig. 13) Insert the receiver into the
mounting bracket with the flat side of the
receiver facing the ceiling.

Step 2. (Fig. 14) Motor to Receiver Electrical
Connections: Connect the black wire from
the fan to black wire marked "TO MOTOR L".
Connect the white wire from the fan to the
white wire marked "TO MOTOR N" from the
receiver. Connect the blue wire from the fan
to the blue wire marked "For Light" from the
receiver. Secure the wire connections with the
plastic wire nuts provided.

Code switch

Receiver

Hanger
bracket

6. INSTALLATION OF SAFETY SUPPORT

(for Canadian Installation ONLY)

An additional safety support is provided to
prevent the fan from falling fan). Place the end
of cable through the loop of ceiling support
cable. Pull as much cable through loop as
possible. Feed end of cable into clamp hole
and fi rmly tighten screw (Fig. 11). Cut off
excess safety cable. Secure the safety cable
to the ceiling joist with screw and washer.

Hanger bracket

Attach safety cable
to ceiling joist with
screw and washer

This manual is related to the following products: