27
26
11.
D
EFAULT
A
LARM
S
ETTINGS
GAS
LOW ALARM
HIGH ALARM
O
2
19.5%
23.5%
LEL
10%
20%
CH
4
1.0%
1.5%
CO
35 PPM
70 PPM
H
2
S
10 PPM
20 PPM
SO
2
2.0 PM
4.0 PPM
NO
2
3.0 PPM
6.0 PPM
Cl
2
0.5 PPM
1.0 PPM
ClO
2
0.3 PPM
1.0 PPM
NOTE: Factory alarm settings may not coincide with
local regulations. Consult all appropriate local
regulations for appropriate alarm settings in
your region.
10.
S
PECIFICATIONS
C
ASE
:
Type 304 Stainless Steel
D
IMENSIONS
:
8.2”L x 3.7”W x 3.2”H
(208 X 94 X 81 mm)
W
EIGHT
:
3.4 lbs (1.5 kg)
S
ENSORS
:
Combustible Gases and Methane-
Catalytic
Oxygen and Toxic Gases-
Electrochemical
M
EASURING
R
ANGE
:
LEL (Combustible Gases)
0 to 100% LEL in 1% increments
CH
4
(Methane)
0 to 5% of volume in 0.1% increments
O
2
(Oxygen)
0 to 30% of volume in 0.1% increments
CO (Carbon Monoxide)
0 to 999 PPM (parts per million) in 1 PPM increments
H
2
S (Hydrogen Sulfide)
0 to 999 PPM (parts per million) in 1 PPM increments
SO
2
(Sulfur Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
NO
2
(Nitrogen Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
C1
2
(Chlorine)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
C1O
2
(Chlorine Dioxide)
0 to 99.9 PPM (parts per million) in 0.1 PPM increments
P
OWER
S
OURCE
: Rechargeable, replaceable nickel-cadmium battery
pack, or replaceable cell alkaline battery pack
B
ATTERY
L
IFE
:
With Nicad Battery Pack - 16 hours typical
With Alkaline Battery Pack - 20 hours typical
R
EADOUT
:
Alpha-Numeric Liquid Crystal Display
T
EMPERATURE
R
ANGE
:
-20ºC to 50ºC (-4ºF to 122ºF)
With H
2
S Sensor
-40ºC to 50ºC (-40ºF to 122ºF)
H
UMIDITY
R
ANGE
:
0% to 99% RH (Non-condensing)
S
TORAGE
T
EMPERATURE
: 0ºC to 20ºC (32ºF to 68ºF)
P
ART
N
UMBER
D
ESCRIPTION
(Q
TY
)
1705-0788-PPM
Combustible Sensor
1705-0129
Oxygen Sensor
1704-1898
Hydrogen Sulfide Sensor
1704-1880
Carbon Monoxide Sensor
1704-1914
Chlorine sensor
1704-4204
CLO
2
sensor
1704-1922
Nitrogen Dioxide Sensor
1704-1906
Sulfur Dioxide Sensor
1810-1386
Stainless Steel Extendible Probe - 6ft.
1810-1428
Polycarbonate Probe
1705-9494
Rechargeable Nicad Battery Pack
1705-9312
Replaceable Alkaline Battery Pack (6 C-cell)
1810-3259
Leather Carrying Case for ATX612
1810-0628
Shoulder Strap
1810-2921
Carrying Handle for ATX612
1810-1154
External Audible/Visual Alarm
1810-2146
External Vibrating Alarm
1810-2187
Cylinder Cal. Gas, H
2
S, CO, Pentane and Oxygen
1810-1576
Cylinder, Cal. Gas, Carbon Monoxide, Pentane and Oxygen
1810-2165
Cylinder, Cal. Gas, Carbon Monoxide, Methane and Oxygen
1810-1584
Cylinder, Cal. Gas, Zero Air
1810-2222
Cylinder, Cal. Gas, 5 PPM Sulfur Dioxide
1810-1758
Cylinder, Cal. Gas, 10 PPM Chlorine
1810-2219
Cylinder, Cal. Gas, 5 PPM Nitrogen Dioxide
1810-2509
Demand Flow Regulator with Pressure Gauge
12.
ATX612 O
PTIONS
& O
RDERING
I
NFORMATION