beautypg.com

Cleaning and maintenance, Cleaning, Replacing coal brushes – Powerplus POWX1152 HAMMER DRILL 1250W EN User Manual

Page 7: Technical data, Noise, Powx1152, 9 cleaning and maintenance, 10 technical data, 11 noise

background image

POWX1152

EN

Copyright © 2014 VARO NV

P a g e

| 7

www.varo.com

Important! When hammer drilling you will require a low pressure. Too much
pressure will place unnecessary load on the motor. Check the drill bits
regularly. Re-sharpen or replace blunt drill bits.

9 CLEANING AND MAINTENANCE

Attention !Before performing any work on the equipment, pull the power
plug.

9.1

Cleaning

 Keep the ventilation slots of the machine clean to prevent overheating of the engine.
 Regularly clean the machine housing with a soft cloth, preferably after each use.
 Keep the ventilation slots free from dust and dirt.
 If the dirt does not come off use a soft cloth moistened with soapy water.

Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.

9.2

Replacing Coal Brushes

Remove and check the carbon brushes regurarly. Replace when they have worn down to the
limit mark. Keep the carbon brushes clean and free to slip in the holders. Both carbon
brushes must be replaced at the same time. Only use original carbon brushes.

10 TECHNICAL DATA

Rated Voltage

220-240 V

Rated Frequency

50 Hz

Rated Power

1250 W

Rotation speed

800 min

-1

Protection class

II

Drill capacity concrete

30 mm

Drill capacity steel

13 mm

Drill capacity wood

40 mm

Impact rate

3900 min

-1

Cable length

3 m + VDE plug

Chuck type

13 mm Keyless chuck

11 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

92 dB(A)

Acoustic power level LwA

103 dB(A)

ATTENTION!

Wear

hearing

protection

when

sound

pressure

is

over 85 dB(A).

aw (Vibration)

15,1 m/s²

K = 1,5 m/s²

This manual is related to the following products: