beautypg.com

Cleaning and maintenance, Cleaning, Technical data – Powerplus POWX111 ELECTRIC PLANER 1020W EN User Manual

Page 6: Noise, Service department, Storage

background image

POWX111

EN

Copyright © 2014 VARO

P a g e

| 6

www.varo.com

9 CLEANING AND MAINTENANCE

Attention !Before performing any work on the equipment, pull the power
plug.

9.1

Cleaning

 Keep the ventilation slots of the machine clean to prevent overheating of the engine.
 Regularly clean the machine housing with a soft cloth, preferably after each use.
 Keep the ventilation slots free from dust and dirt.
 If the dirt does not come off use a soft cloth moistened with soapy water.

Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.

10 TECHNICAL DATA

Voltage / frequency

230V / 50Hz

Power input

1020W

No load speed

16000rpm

Planing width

82mm

Max Planing depth

3mm

Weight

3.15 kg

11 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

91 dB(A)

Acoustic power level LwA

102 dB(A)

ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).

aw (Vibration)

3.2 m/s²

K = 1,5 m/s²

12 SERVICE DEPARTMENT

 Damaged switches must be replaced by our after-sales service department.
 If the connecting cable (or mains plug) is damaged, it must be replaced by a particular

connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).

13 STORAGE

 Thoroughly clean the whole machine and its accessories.
 Store it out of the reach of children, in a stable and secure position, in a cool and dry

place, avoid too high and too low temperatures.

 Protect it from exposure to direct sunlight. Keep it in the dark, if possible.

Don’t keep it in plastic bags to avoid humidity build-up.