8 TECHNICAL DATA
Mains voltage
230-240V
Mains frequency
50Hz
Power rating
300W
No load speed
6000-11000 min
-1
Sanding surface
90 X 90 X 90 mm
Weight
1.2 kg
Safety class
II
9
NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
81 dB(A)
Acoustic power level LwA
92 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration)
9.7 m/s²
K = 1,5 m/s²
10 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
10.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
11 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
12 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build-up.