Cooling down, Maintenance and cleaning, Maintenance – Powerplus POW703 HEAT GUN 1600W EN User Manual
Page 7: Lubrication, Cleaning, Technical data

POW703
EN
Copyright © 2014 VARO
P a g e
| 7
www.varo.com
Do not keep the tool directed at one spot too long to prevent igniting the
surface.
Avoid collecting paint on the scraper accessory, as it may ignite. If
necessary, carefully remove paint debris from the scraper accessory using
a knife.
9.4
Cooling down
The nozzle and accessory become very hot during use. Let them cool down before attempting
to move or store the tool.
To reduce the cooling time, switch the tool on at the lowest air temperature setting and let
in run for a few minutes.
Switch the tool off and let it cool down for at least 30 minutes.
10 MAINTENANCE AND CLEANING
Attention !Before performing any work on the equipment, pull the power
plug.
10.1
Maintenance
Your Power Tool has been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper tool care and regular
cleaning
10.2
Lubrication
Your power tool requires no additional lubrication
10.3
Cleaning
Before cleaning, let the tool cool down
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
11 TECHNICAL DATA
Voltage
230V
– 50 Hz
Power supply
1600 W
Airtemperature / Flow
Low 380° /* 300 l/min
High 500° /* 500 l/min