10 OPERATION
DANGER : Before operation : connect your generator to earth! This way you
will avoid static charges (possible electric shock) and will enable protective
devices to respond (e.g. leakage current trip switches) on the appliances
being connected.
Use a shielded conducting cable with a minimum cross-section of 1.5 mm² to connect your
generator to an earthing point (e.g. a water or heating pipe). Connect the conductor to the
earthing connection on your generator and tighten it securely.
CAUTION : The generator has been shipped without engine oil. Fill with oil
or it will not start.
10.1
Starting the engine
NOTE: Before starting the engine, Disconnect all loads from the generator.
§ Turn the fuel cock to “ON”.
§ Turn the engine switch to “ON”
§ Turn the choke lever to the left to the |
| (min) position. Not necessary if the engine is
warm.
§ Pull the starter handle slowly until resistance is felt. This is the “Compression” point.
Return the handle to its original position and pull swiftly . Do not fully pull out the rope.
After starting, allow the starter handle to return to its original position while still holding the
handle.
§ If the motor does not start immediately, repeat step 4
§ Warm up the engine.
§ Turn the choke lever back to the operating position.
§ Allow the engine to warm up for a few minutes without a load.
If the motor does not start after about 5 attempts, please refer to the section
"Trouble-shooting"
10.2
Connecting electric tools/appliances
Insert the plug(s) of the electrical appliance(s) into the power socket. (lift the protective lid of
the socket and and plug in the load.
CAUTION:
Be sure the electric appliance is turned off before plugging in.
Be sure the total load is within generator rated output.
Be sure the socket load current is within socket rated current.
NOTE :
When the circuit breaker is switched off during operation, the generator was overloaded or a
short circuit occurred (example. connected machine may be defect).
Stop the generator immediately, check the connected power , diminish when it exceeds the
rated generator output. Check the power tool. Allow to cool down for a few minutes before
you switch the circuit breaker back to “ON”.
10.3
Stopping
§ Turn off the power switch of the electric apparatus or unplug the cord from the socket of
the generator.
§ Turn the engine switch to “OFF”.
§ Turn the fuel cock lever to “OFF”.