Powerplus POW4761 POWER G ENERATOR 2200W EN User Manual
Page 6

POW4761(SC)
EN
Copyright © 2012 VARO
P a g e
| 6
§ If you swallow any fuel, inhale fuel vapor, or allow any to get in your eyes, see your doctor
immediately. If any fuel spills on your skin or clothing, immediately wash with soap and
water and change your clothes.
§ When operating or transporting the machine, be sure it is kept upright. If it tilts, fuel may
leak from the carburetor or fuel tank.
6.4
Engine and muffler can be very hot
Danger for burning :
§ Place the machine in a place where pedestrians or children are not likely to touch the
machine.
§ Avoid placing any flammable materials near the exhaust outlet during operation.
§ Keep the machine at least 1 m ( 3 ft ) from buildings or other equipment, or the engine
may overheat.
§ Avoid operating the engine with a dust cover.
§ After operation, allow to cool down before storage
6.5
Electric shock prevention
Danger of electric shock
§ Incorrect electric installation can lead to electric shock !
§ Never operate the engine in rain or snow.
§ Never touch the machine with wet hands or electrical shock will occur.
§ Be sure to ground (earth) the generator.
6.6
Connection notes
§ Avoid connecting the generator in parallel to the commercial mains power network.
§ Avoid connecting the generator in parallel with any other generator.
6.7
Personal protection
§ Please wear the earplug when operate the machine.
7
ELECTRICAL SAFETY: IP23
8
CONTROL FUNCTIONS
8.1
Oil warning system
When the oil level falls below the lower level, the engine stops automatically. Unless you refill
with oil, the engine will not start again.
8.2
Engine switch
The engine switch controls the ignition system.
§ “ON”(run) : Ignition circuit is switched on. The engine can be started.
§ “OFF”(stop) : Ignition circuit is switched off. The engine can not run.
8.3
Ac protector (ac circuit breaker)
The AC PROTECTION turns off automatically when:
§ the load exceeds the generators rated output.
§ In case of short circuit
CAUTION Reduce the load to within specified generator rated output if the AC PROTECTOR
turns off.