10.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10.2
Carbon brushes
The brushes should be checked periodically and worn-out brushes should be replaced by
qualified personnel in time.
10.3
mains cable & plug
If the connecting cable (or mains plug) is damaged, it must be replaced. Replacement of the
connecting cable should only be carried out by a qualified specialist (qualified electrician).
11 TECHNICAL DATA
POWXQ5205
Mains voltage
230-240V ~ 50Hz
Power input
1200W
No load speed
0-1000 min-1 / 0-2800 min-1
chuck capacity :
Max. 13 mm
Impact rate (+/-)
0-19000/0-53200 min-1
Double isolated
yes
Degree of protection
IP20
Max. drill capacity in :
concrete
16mm
wood
30mm
steel
13mm
Weight
3.90 kg
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
96 dB(A)
Acoustic power level LwA
107 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration)
13.4 m/s²
1.5 m/s²
13 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.