beautypg.com

Sanding, Scraping, Cleaning and maintenance – Powerplus POWX1345 MULTI-USE TOOL 300W EN User Manual

Page 7: Technical details, Noise

background image

POWX1345

EN

Copyright © 2014 VARO

P a g e

| 7

www.varo.com

8.3.3

Sanding

The removal rate and the sanding pattern are primarily determined by the choice of sanding
sheet, the preset oscillation rate and the applied pressure.
Only flawless sanding sheets achieve good sanding capacity and extend the service life of the
machine.
Pay attention to apply uniform sanding pressure; this increases the working life of the sanding
sheets.
Intensifying the sanding pressure does not lead to an increase of the sanding capacity, but to
increased wear of the machine and the sanding sheet.
For precise on-the-spot sanding of edges, corners and hard to reach areas, it is also possible
to work only with the tip or an edge of the sanding plate.
When selectively sanding on the spot, the sanding sheet can heat up considerably. Reduce
the orbital stroke rate and allow the sanding sheet to cool down regularly.
A sanding sheet that has been used for metal should not be used for other materials.

8.3.4

Scraping

For scraping, select a high oscillation rate.
Work on a soft surface (e.g. wood) at a flat angle and apply only light pressure. Otherwise the
scraper can cut into the surface.

9 CLEANING AND MAINTENANCE

Before performing any work on the equipment, pull the power plug.

Keep the ventilation slots of the machine clean to prevent overheating of the engine.

Regularly clean the machine housing with a soft cloth, preferably after each use.

Keep the ventilation slots free from dust and dirt.

If the dirt does not come off use a soft cloth moistened with soapy water.

Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may
damage the plastic parts.

Make sure no water can reach the inside of the power tool!

10 TECHNICAL DETAILS

Model nr.

POWX1345

Voltage

230V

Mains frequency

50 Hz

Power

300W

No load speed

15 000-22 000 min-1

11 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

84 dB(A)

Acoustic power level LwA

95 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

aw (Vibration)

4.4 m/s²

K = 1,5 m/s²