beautypg.com

Technical data, Noise, Troubleshooting – Powerplus POWAIR0806 PNEUMATIC STAPLER/NAILER EN User Manual

Page 5

background image

POWAIR0806

EN

Copyright © 2014 VARO

P a g e

| 5

www.varo.com

 Air-operated tools must be inspected periodically, and worn or broken parts must be

replaced to keep the tool operating safely and efficiently. Check and change all worn or
damaged O-ring, Seals, etc. Tight all the screws and caps in case personal injury.

 Make regular inspection for free movement of trigger, Spring and safety mechanism to

assure safe system is complete and functional: no loose and missing parts, no building
or stocking parts.

 Keep magazine and nose of tool clean and free of any dirt lint or abrasive particles.
 When temperatures are below freezing, tools should be kept warm by any convenient,

safe method.

9

TECHNICAL DATA

Model

POWAIR0806

Activation mode

Single sequential action

Max. allowable pressure

120PSI(8.3 bar)

Operating pressure

60-100PSI(4-7bar)

Air inlet size

¼”

Avg. air consumption

65l/min(2.29cfm)

Recommended lubricant

White mineral oil

Nail capacity

100pcs

10

NOISE

Noise emission values measured according to relevant standard. (K=2.5)

Acoustic pressure level LpA

89 dB(A)

Acoustic power level LwA

102 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

aw (Vibration) :

1.9 m/s²

K= 0.5 m/s²

11

TROUBLESHOOTING

SYMPTOM

PROBLEM

SOLUTIONS

Air leak
near top of tool or in
trigger area

O-ring in trigger valve is
damaged.

Check and replace O-ring.

Trigger valve head are
damage.

Check and replace.

Trigger valve stem, seal or
O-ring are damaged.

Check and replace trigger
valve stem, seal or O-ring

Air leak near bottom of
tool.

Loose screws.

Tighten screws.

Worn or damaged O-rings or
bumper.

Check and replace O-rings
or bumper.

Air leak between body

Loose screws.

Tighten screw.