It is most important that the tool be properly lubricated by keeping the air line lubricator
filled and correctly adjusted. Without proper lubrication the tool will not work properly
and parts will wear prematurely.
Use the proper lubricant in the air line lubricator. The lubricator should be of low air flow
or changing air flow type, and should be kept filled to the correct level. Use only
recommended lubricants, specially made for pneumatic applications. Substitutes may
harm the rubber compounds in the tools, O-rings and other rubber parts.
6
IMPORTANT!!!
If no filter/ pressure regulator/ lubricator is installed in the compressed air system, then
pneumatic tools must be lubricated with 2 to 6 drops of oil at least once a day or after
every two hours of use. This must be done directly along the male coupler or the screw
(OIL) provi
ded for the purpose on the side of the tool’s housing.
Automatic lubrication is also possible using the supplied mini oiler that you have to install
between the threaded connector of the tool and the male coupler. Make sure that the oiler
is always filled with suitable oil.
Fig. 1
1.
Tool
2.
Quick connector
3.
Quick coupler
4.
Air hose
5.
Quick connector
6.
Quick coupler
7.
Lubricator
8.
Regulator (0-8.5 bar)
9.
Filter
10.
Cut-off valve
11.
Air compressor
7
TOOL USE
1.
Read "Safety Warnings" before using tool
2.
Push magazine lock lever and slide upper magazine to open magazine. (Fig. 2)
3.
Place strip of nails or staples into the magazine with the point resting on the fastener
guide. Do not load with trigger depressed. (Fig. 3)
4.
Push upper magazine back until magazine lock latches. (Fig. 4)
5.
Keep the nailer pointed away from yourself and others and connect to the hose.
6.
Position the nailer nose against work piece and pull the trigger
7.
Disconnect air supply in case a nail or stapler is jammed
8.
Loosen screws on the nose with the hex key and remove the front part. (Fig. 5)
Remove jammed nails or staples and close the front cover.
9.
Keep the tool pointed away from yourself and others and connect back to the hose.
8
MAINTENANCE
Disconnect the tool from the compressor before adjusting, clearing jams,
servicing &maintenance, relocating and during non operation.
Regular lubrication, if your tool without using the in-liner automatic oilier, place 2 or 6
drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of
continuous use depending in the characteristic of work piece or type of fasteners.