Maintenance, Technical data, Noise – Powerplus POWAIR0805 PNEUMATIC MULTI-USE TOOL EN User Manual
Page 8: Troubleshooting
POWAIR0805
EN
Copyright © 2014 VARO
P a g e
| 8
www.varo.com
10
MAINTENANCE
WARNING: Disconnect wrench from air supply before changing
accessories, servicing or performing maintenance. Replace or repair
damaged parts. Use genuine parts only. Non-authorised parts may be
dangerous.
1.
Lubricate the air wrench daily with a few drops of air tool oil dripped into the air inlet
2.
DO NOT use worn or damaged sockets.
3.
Loss of power or erratic action may be due to the following:
4.
Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size
or type of hose connectors. To remedy check the air supply and follow instructions.
5.
Grit or gum deposits in the wrench may also reduce performance. If your model has
an air strainer (located in the area of the air inlet), remove the strainer and clean it.
6.
When not in use, disconnect from air supply, clean wrench and store in a safe, dry,
childproof location.
11
TECHNICAL DATA
Model
POWAIR0805
No load speed
18000 min
-1
Air pressure
6.2 bar / 90 psi
Air inlet size
¼”
Avg. air consumption
180 l/min
12
NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
88 dB(A)
Acoustic power level LwA
99 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration) :
4,5 m/s²
13
TROUBLESHOOTING
The following form lists the common operating system with problem and solutions. Please
read the form carefully and follow it.
WARNING: If any of the following symptoms appears during your
operating, stop using the tool immediately, or serious personal injury
could result. Only a qualified persons or an authorized service center can
perform repairs or replacement of tool.