TECHNICAL DATA

Model

POWAIR0311

Activation mode

Single sequential action

Max. allowable pressure

120PSI(8.3 bar)

Operating pressure

60-100PSI(4-7bar)

Air inlet size

¼”

Avg. air consumption

78.68l/min(2.78cfm)

Recommended lubricant

White mineral oil

Nail capacity

100pcs

10

NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

87 dB(A)

Acoustic power level LwA

100 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

aw (Vibration)

2.9 m/s²

K = 0.02 m/s²

11

TROUBLESHOOTING

SYMPTOM

PROBLEM

SOLUTIONS

Air leak
near top of tool or in
trigger area

O-ring in trigger valve is
damaged.

Check and replace O-ring.

Trigger valve head are
damage.

Check and replace.

Trigger valve stem, seal or
O-ring are damaged.

Check and replace trigger
valve stem, seal or O-ring

Air leak near bottom of
tool.

Loose screws.

Tighten screws.

Worn or damaged O-rings or
bumper.

Check and replace O-rings
or bumper.

Air leak between body
and cylinder cap.

Loose screws.

Tighten screw.

Worn or damaged O-rings or
seals.

Check and replace O-rings
or bumper.

Blade driving fastener
too deep.

Worn bumper.

Replace bumper.

Air pressure is too high.

Adjust the air pressure.

Tool does not operate
well: can not drive

Inadequate air supply.

Verify adequate air supply.

Inadequate lubrication.

Place 2 or 6 drops of oil into