Technical data, Noise, Troubleshooting – Powerplus POWAIR0311 PNEUMATIC STAPLER/NAILER EN User Manual
Page 6

POWAIR0311
EN
Copyright © 2014 VARO
P a g e
| 6
www.varo.com
When temperatures are below freezing, tools should be kept warm by any convenient,
safe method.
9
TECHNICAL DATA
Model
POWAIR0311
Activation mode
Single sequential action
Max. allowable pressure
120PSI(8.3 bar)
Operating pressure
60-100PSI(4-7bar)
Air inlet size
¼”
Avg. air consumption
78.68l/min(2.78cfm)
Recommended lubricant
White mineral oil
Nail capacity
100pcs
10
NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
87 dB(A)
Acoustic power level LwA
100 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration)
2.9 m/s²
K = 0.02 m/s²
11
TROUBLESHOOTING
SYMPTOM
PROBLEM
SOLUTIONS
Air leak
near top of tool or in
trigger area
O-ring in trigger valve is
damaged.
Check and replace O-ring.
Trigger valve head are
damage.
Check and replace.
Trigger valve stem, seal or
O-ring are damaged.
Check and replace trigger
valve stem, seal or O-ring
Air leak near bottom of
tool.
Loose screws.
Tighten screws.
Worn or damaged O-rings or
bumper.
Check and replace O-rings
or bumper.
Air leak between body
and cylinder cap.
Loose screws.
Tighten screw.
Worn or damaged O-rings or
seals.
Check and replace O-rings
or bumper.
Blade driving fastener
too deep.
Worn bumper.
Replace bumper.
Air pressure is too high.
Adjust the air pressure.
Tool does not operate
well: can not drive
Inadequate air supply.
Verify adequate air supply.
Inadequate lubrication.
Place 2 or 6 drops of oil into