beautypg.com

Lubrication – Powerplus POWAIR0340 PNEUMATIC NAILER EN User Manual

Page 4

background image

POWAIR0340

EN

Copyright © 2011 VARO

P a g e

| 4

www.varo.com

4.

Unlatch the magazine lock lever and a spring will bring the
lever back i

n it’s first position.

5.

Keep the nailer pointed away from yourself and others
and connect to the hose.

6.

Position the nailer nose against work piece and pull the
trigger

7.

Disconnect air supply in case a nail is jammed

8.

Pull the grease shaft and pull the front part of the nailer
nose open. Remove jammed nails and close the front
cover again.

9.

Keep the tool pointed away from yourself and others and
connect back to the hose.

6

LUBRICATION

An automatic in-line filter-regulator-lubricator is recommended (Fig4) as it increases tool
life and keeps the tool in sustained operation. The in-line lubricator should be regularly
checked and filled with air tool oil.
Proper adjustment of the in-line lubricator is performed by placing a sheet of paper next to
the exhaust ports and holding the throttle open approximately 30 seconds. The lubricator
is properly set when a light stain of oil collects on the paper. Excessive amounts of oil
should be avoided.