Electrolux EWF 12040 W User Manual
Page 23
Cleaning the pump
The pump should be inspected if
• the machine does not empty and/or
spin
• the machine makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump.
Proceed as follows:
• Disconnect the appliance.
• If necessary wait until the water has
cooled down.
• Open the pump door.
• Place a containfer close to the pump
to collect any spillage.
• Pull out the emergency emptying
hose, place it in the container and
remove its cap.
• When no more water comes out,
unscrew the pump cover and remove
it. Always keep a rag nearby to dry up
spillage of water when removing the
cover.
P1114
• Remove any objects from the pump
impeller by rotating it.
• Put the cap back on the emergency
emptying hose and place the latter
back in its seat.
• Screw the pump cover fully in.
• Close the pump door.
Warning!
When the appliance is in use and
depending on the programme selected
there can be hot water in the pump.
P1117
P1115
23 electrolux care and cleaning