beautypg.com

Enerco UNVENTED NATURAL GAS FIRED ROOM HEATER TSIR20NGT User Manual

Page 10

background image

10

Installation Instructions and Owner’s Manual

Unvented Natural Gas Fired Room Heater

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If knob will not

push in or turn by hand, don’t try to repair it; call

a qualified service technician or gas supplier.

Force or attempted repair may result in a fire or

explosion.

D. Do not use this appliance if any part has been

underwater. Immediately call a qualified service

technician to inspect the appliance and to re-

place any part of the control system which has

been underwater.

LIGHTING INSTRUCTIONS

1.

STOP! Read the all safety information included

with and on the side of heater.

2. Check that gas supply to heater is on.
3. Push in gas control knob and slightly turn clock-

wise to the OFF position (see figure 16).

Note: Knob cannot be turned from PILOT to OFF

unless knob is pushed in slightly. Do not force.
4. Wait five (5) minutes. Then smell for gas, in-

cluding near the floor. If you smell gas,

STOP!

Follow “B” in the safety information above. If

you do not smell gas, go to the next step.

5. Push in gas control knob slightly and turn coun-

terclockwise to PILOT/IGN and depress for five

(5) seconds.

Note: The first time that the heater is operated after

connecting the gas supply, the control knob should

be depressed for about 30 seconds. This will allow

air to bleed from the gas system.
6. Push in control knob and rotate control knob

back to OFF position then rotate counterclock-

wise to PILOT/IGN position. This will light pilot.

If needed gently keep rotating control knob

back and forth while depressed until pilot lights.

7. Keep control knob depressed in for ten (10)

seconds after lighting pilot. If pilot goes out,

repeat steps 4, 5, 6 and 7.

If pilot does not stay lit, refer to Troubleshoot-

ing, pages 14 & 15. Also, contact a qualified

service person or gas supplier for repairs.

If control knob does not pop up when released,

contact a qualified service person or gas sup-

plier for repairs.

8. FOR IR10NG: When the pilot is lit, turn the con-

trol knob to “LO” position to light heater. Leave

on “LO” position until first burner tile has turned

bright red (Figure 18)

FOR BF6NG and BF10NG: When the pilot is

lit, turn the control knob to “HI” position to light

heater.

9. FOR IR10NG: After first burner tile has turned

bright red, adjust heat output by turning control

knob to desired position (“LO” or “HI”). Do not

operate heater between locked positions.

FOR BF6NG and BF10NG: After flame is estab-

lished (see Burner Flame Pattern,

Page 12) on

“HI”, adjust heat output by turning control knob

to desired position (“LO” or “HI”). Do not operate

heater between locked positions.

Figure 16

Figure 17

CAUTION: Do not try to adjust heating level by using

equipment shutoff valve.

Control Knob

LOW

HIGH

OFF

Control Knob

Figure 18

Burner tile pattern

for IR only.