Excell precision co., ltd – Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User Manual
Page 12

EXCELL PRECISION CO., LTD
.
Weighing
ZSME300000036
10
2. Weight of Known Container ( PRETARE )
Œ Press PRETARE key, and the screen displays п
р
.
. Use
BL/↑ , G/N/↓ , TARE/← , ZERO/→ , ENTER , ESC keys to input
the presetting value. The functions are described as below:
Input the weight of container. After finished, the screen displays the negative
value of the container, and the net weight (Net) and pre-tare (PT) indications light
up.
• Place both the object and container on platter, and the scale displays the net
weight of it.
Ž
“Pre-tare value” clearing
Press RECALL , PRETARE and then CE
⇒
to clear
“pre-tare” value.
The scale will be re-zeroed and net weight (Net) and pre-tare (PT) indications
disappear.
•
“Pre-tare” recall
Press RECALL and then PRETARE
⇒
the screen displays
“pre-tare”
value.
4
Pre-tare function is not available under tare mode.
4
If it has segments,
“pre-tare” value can’t be larger than the segment value.