beautypg.com

Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User Manual

Page 11

background image

EXCELL PRECISION CO., LTD

.

Weighing

ZSME300000036

9

(6). Low Voltage Auto Power off Function

Œ When the voltage of batteries is lower than 5.6v±0.1 v, it turns off backlight and

the screen displays the battery symbol to intimate it needs to be recharged.

• When the voltage of batteries is lower than 5.4v±0.1 v, it would auto power off;

meanwhile, if turning on again, the screen would not be countdown and only

displays the battery symbol. It would auto power off after 5 seconds, and it

needs to recharge immediately.

Ž When the voltage of batteries is lower than 5.2v±0.1 v, it can

’t be turned on and

please recharge immediately.

(7). Tare Function

1. Weight of Unknown Container ( TARE/← )

Œ Place the container on platter. After being stable, press TARE/← key to

re-zero. The screen will display net weight (Net) indication.

• Place the object into the container, and the scale will display the net weight of it.

Ž

“Tare value” clearing

Remove both the container and the object on the platter; the scale displays the

negative value of the container. Meanwhile, press TARE/← again to clear

“tare value,” and the net weight (Net) indication disappears.

“Tare value” recall

Press RECALL and then TARE/←

The screen displays

“tare value”.

4

Capable of continuously taring until the summation of tare and pre-tare value

equals the capacity of the scale.

4

Continuously tare function

both continuously increasing or decreasing

weight on platter are acceptable by pressing TARE/← key.