Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User Manual
Page 11

EXCELL PRECISION CO., LTD
.
Weighing
ZSME300000036
9
(6). Low Voltage Auto Power off Function
Œ When the voltage of batteries is lower than 5.6v±0.1 v, it turns off backlight and
the screen displays the battery symbol to intimate it needs to be recharged.
• When the voltage of batteries is lower than 5.4v±0.1 v, it would auto power off;
meanwhile, if turning on again, the screen would not be countdown and only
displays the battery symbol. It would auto power off after 5 seconds, and it
needs to recharge immediately.
Ž When the voltage of batteries is lower than 5.2v±0.1 v, it can
’t be turned on and
please recharge immediately.
(7). Tare Function
1. Weight of Unknown Container ( TARE/← )
Œ Place the container on platter. After being stable, press TARE/← key to
re-zero. The screen will display net weight (Net) indication.
• Place the object into the container, and the scale will display the net weight of it.
Ž
“Tare value” clearing
Remove both the container and the object on the platter; the scale displays the
negative value of the container. Meanwhile, press TARE/← again to clear
“tare value,” and the net weight (Net) indication disappears.
•
“Tare value” recall
Press RECALL and then TARE/←
⇒
The screen displays
“tare value”.
4
Capable of continuously taring until the summation of tare and pre-tare value
equals the capacity of the scale.
4
Continuously tare function
⇒
both continuously increasing or decreasing
weight on platter are acceptable by pressing TARE/← key.