Optical effects module – Elation Professional 700 II User Manual
Page 51
Power Spot 700 II™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
51
13. OPTICAL EFFECTS MODULE
The Power Spot 700 II is equipped with an optical effects module that can be easily
removed for cleaning, service, and gobo/color exchange. Please follow the procedures
below for proper removal and service of the effects module.
13.1 Safety considerations
• Always remove main power before attempting any type of service procedure.
• If the fixture has been recently in operation, please allow 15 minutes for the
internal components to cool before attempting service.
• During service never touch the lamp with bare fingers as this can damage the
lamp and reduce lamp life.
• To prevent personal injury from UV radiation, always be sure the cover is
replaced before operating the fixture.
13.2 Removing the optical effects module:
1) Please lock the head in a vertical position for easier access.
2) Remove the upper shell of the head casing by loosening the four quick-release
retaining fasteners. Two on the front side and two on the backside of the head.
Hang out the head safety.
3) Disconnect the main "Data Bus" cable from the optical effects module. This is the
only connection between the effects module and the fixture’s head control board.
No other bus cables need to be removed. See illustration below;
4x 90°