Troubleshooting guide
Fault
Cause
remedy
Engine does
not start
Automatic oil
cut-out has not
responded
Check oil level,
top up engine oil
Spark plug
fouled
Clean or replace
spark plug
(electrode
spacing 0.6 mm)
No fuel
Refuel / have
the petrol cock
checked
Generator
has too little
or no voltage
Controller or
capacitor
defective
Contact your
dealer
Overcurrent
circuit-breaker
has triggered
Actuate the circuit-
breaker and reduce
the consumers
Air filter dirty
Clean or replace
the filter
Maintenance schedule
Please adhere to the following maintenance periods
in order to ensure a failure-free operation.
IMPOrTANT! The equipment must be
filled with engine oil and fuel before it
is started.
before each
use
After an
operating
period of
20 hours
After an
operating
period of
50 hours
After an
operating
period of
100 hours
After an
operating
period of
300 hours
Checking the
engine oil
X
Changing the
engine oil
For the first
time, then every
50 hours
X
Checking the
air filter
X
Change the
filter insert if
necessary