Storing the engine, Overload protection 2 x 230 v sockets, Cleaning – Parkside PSE 2800 A1 User Manual
Page 32: Air filter, Spark plug (fig. m–n)
32 GB
Cleaning, maintenance, storage, transport and ordering replacement parts
... / Cleaning, maintenance, storage, transport and ordering replacement parts
Note: Some electric devices (sabre saws, drills etc.)
can use more electricity when doing heavy duty tasks.
Storing the engine
Before putting away, let the generator run with-
out load so that the device can „cool down“.
Turn the on / off switch
11
to the „OFF“ position.
Close the petrol tap
14
.
Overload protection
2 x 230 V sockets
WArNING! This generator is fitted
with an overload protector.
This cuts off the sockets
3
. By activating the over-
load switch
6
the sockets
3
can be used again.
ATTENTION! If this happens reduce the
amount of electrical output which you are
extracting from the generator or remove
defective devices which are attached.
ATTENTION! Faulty overload switches
should only be replaced with identically
constructed overload switches with the
same performance data. Please use our
customer service department.
Cleaning, maintenance, stor-
age, transport and ordering
replacement parts
Before cleaning and maintenance work, turn off the
engine and pull the spark plug connector
28
out of
the spark plug
27
.
ATTENTION! Turn the device off imme-
diately and contact your Service Station:
- With unusual vibrations or noises.
-
If the engine seems overloaded or has backfired.
Cleaning
Keep the safeguards, air vents (fig. B / Pos. B1)
and the engine housing as dust and dirt free as
possible. Wipe the device with a clean cloth or
blow it with compressed air with low pressure.
We recommend that you clean the device after
every use.
Regularly clean the device with a damp cloth
and a little soft soap. Do not use any cleaning
products or solvents which could attack the plas-
tic part of the device. Ensure that no water can
penetrate the housing.
Air filter
Also refer to the service information.
Clean the air filter regularly, and if necessary
exchange it.
Open both brackets (fig. K / Pos. K1) and remove
the air filter lid (fig. K / Pos. K2).
Remove the filter element (fig L / Pos. L1).
When cleaning the element do not use any strong
cleaners or petrol.
Clean the element by tapping it on a flat surface.
If it is very dirty wash with soapy water, rinse
with clean water and leave to dry.
Put it back together in the opposite order.
Spark plug (fig. M–N)
Check the spark plug
27
after the first 20 hours of
use for dirt and if necessary clean it with a copper
wire brush. Then service the spark plug after every
50 hours of use.
Remove the spark plug connector
28
(fig. M)
with a turning movement.
Remove the spark plug
27
(fig. N) with the spark
plug socket
25
included.
Put it back together in the opposite order.
Note: alternative spark plugs to F7RTC:
Bosch WR7DC