beautypg.com

Operation, Gb mt – Parkside PSS 65 A1 User Manual

Page 41

background image

41

GB MT

Mount the sharpener

1. Select one of the three sharpen-

ers.

2. In order to remove a sharpener

from the working position, you

must press down the release le-

ver for the sharpener (13).

3. Remove the sharpener from the

guide rails, upwards.

4. In the storage positions, the

sharpeners are not fixed to the

right and left side and can be

easily removed from the guide

rails.

5. In order to fasten the selected

sharpener in the working posi-

tion, from above push this into

the guide rails. Press the sharp-

ener down until it snaps into

place.

The sharpeners also present

a safety device. Never use

this device without a sharp-

ener. Risk of injury!

Operation

Caution! Risk of injury!

- Always disconnect the plug from

the mains socket before working.

- Use only grinding disks and acces-

sories recommended by the manu-

facturer. The use of other insertion

tools and other accessories may

cause risk of injury.

- Never operate the device without

the visual protection disk.

-

Switch on the equipment only when

it is safely installed on the work sur-

face.

Despite spark protection, al-

ways wear safety goggles

while working in order to

avoid eye injuries.

Keep your hands away from

the grinding disc and grind-

ing belt when the device is in

operation. Injury hazard!.

Switching on and off

Ensure that the mains voltage

matches the specifications on the

rating plate.

Connect the equipment to the mains.

1. To switch on, press the “I” On switch

and the device starts up (see 3).

2. To switch off, press the “0” off switch

and the device switches off (see 3).

After switching on the device, wait until the

device has reached its max. speed. Only

then must you start with the grinding.

The disk will continue to

run after the equipment is

switched off. There is a risk

of injury.

Test run:

Before starting work and after each

change of grinding disk, carry out a test

run of at least 60 seconds with no load.

Switch off the equipment immediately if the

disk runs lumpy, substantial vibrations oc-

cur, or abnormal noises are generated.