beautypg.com

Technical data, Noise and vibration, Residual risks – Parkside PZKS 1500 A1 User Manual

Page 12

background image

7

GB/IE

batteries with household waste. Defective or used

batteries must be recycled according to Directive

2006/66 / EC. Give back batteries and / or the device

has been offered to the collective facilities. About

disposal facilities you can inform by your municipal

or city government.

7

Do not allow batteries to heat up!

8

Do not weld or solder directly on batteries!

9

Do not dismantle batteries!

10 Do not allow batteries to deform!
11

Do not throw batteries into fire!

12 Keep batteries out of the reach of children.
13 Do not allow children to replace batteries without

supervision!

14

Do not keep batteries near fire, ovens or other
sources of heat. Do not use batteries in direct sun-

light or store them in vehicles in hot weather.

15 Keep unused batteries in the original packaging and

keep them away from metal objects. Do not mix

unpacked batteries or toss them together! This can

lead to a short-circuit of the battery and thus dam-
age, burns or even the risk of fire.

16 Remove batteries from the equipment when it will

not be used for an extended period of time, unless

it is for emergencies!

17 NEVER handle batteries that have leaked without

appropriate protection. If the leaked fluid comes into
contact with your skin, the skin in this area should be

rinsed off under running water immediately. Always
prevent the fluid from coming into contact with the
eyes and mouth. In the event of contact, please seek

immediate medical attention.

18 Clean the battery contacts and corresponding con-

tacts in the device prior to inserting the batteries:

6. Technical data

AC motor

220 - 240 V ~ 50Hz

Power

1500 Watt

Operating mode

S6 25%*

Idle speed n

0

5000 min

-1

Carbide saw blade ø 210 x ø 30 x 2,6 mm

Number of teeth

24

Swivel range

-45° / 0°/ +45°

Mitre cut

0° bis 45° nach links

Saw width at 90°

340 x 58 mm

Saw width at 45°

240 x 58 mm

Saw width at 2 x 45°
(double mitre cut)

240 x 32 mm

Protection class

II

Weight

approx. 17 kg

Laser class

2

Wavelength of laser

650 nm

Laser output

≤ 1 mW

Laser module power
supply

2 x 1,5 V Micro (AAA)

* S6, continuous operation periodic duty.

Identical duty cycles with a period at load followed

by a period at no load. Running time 10 minutes;

duty cycle is 25% of the running time.

The work piece must have a minimum height of 3mm

and a minimum width of 10 mm.

Make sure that the workpiece is always secured with

the clamping device.

Noise and vibration

Total vibration values determined in accordance with

EN 61029.

sound pressure level L

pA

99.6 dB(A)

uncertainty K

pA

3 dB

sound power level L

WA

112.6 dB(A)

uncertainty K

WA

3 dB

Wear hearing protection.

The effects of noise can cause a loss of hearing. Total

vibration values (vector sum - three directions) deter-

mined in accordance with EN 61029.

Vibration emission value a

h

4.51 m/s²

uncertainty K

1,5 m/s²

- The specified vibration value was established in ac-
cordance with a standardized testing method. It may

change according to how the electric equipment is
used and may exceed the specified value in exceptio-
nal circumstances;
- The specified vibration value can be used to compare
the equipment with other electric power tools.
- The specified vibration value can be used for initial
assessment of a harmful effect.

Reduce noise generation and vibration to a mini-

mum!

- Use only equipment that is in perfect condition.

- Maintain and clean the equipment regularly.

- Adopt your way of working to the equipment.

- Do not overload the equipment.

- Have the equipment checked if necessary.

- Switch off the equipment when not in use.

Residual risks

The machine has been built according to the state of

the art and the recognised technical safety require-

ments. However, individual residual risks can arise

during operation.

• Health hazard due to electrical power, with the use of

improper electrical connection cables.

• Furthermore, despite all precautions having been met,

some non-obvious residual risks may still remain.

• Residual risks can be minimised if the „safety instruc-

tions“ and the „Proper use“ are observed along with

the whole of the operating instructions.