beautypg.com

Parkside PZKS 1500 A1 User Manual

Page 11

background image

6

GB/IE

The generation of noise is influenced by various
factors, including the characteristics of saw

blades, condition of saw blade and electric

tool. Use saw blades which were designed for

reduced noise development, insofar as possible.

Maintain the electric tool and tool attachments

regularly and if necessary, initiate repairs in

order to reduce noise.

– Report faults on the electric tool, protective

devices or the tool attachment to the person

responsible for safety as soon as they are dis-

covered.

3 Safe work

– Only use saw blades for which the maximum

permissible speed is not lower than the maxi-

mum spindle speed of the machine and which

are suitable for the material to be cut.

– Make sure that the saw blade does not touch

the rotary table in any position by pulling out the

mains plug and rotating the saw blade by hand

in the 45° and 90° position. If necessary, read-

just the saw head.

– When transporting the electric tool, only use

the transport devices. Never use the protective

devices for handling or transport.

– Make sure that the lower part of the saw blade is

covered during transport, e.g. by the protective

device.

– Be sure to only use spacers and spindle rings

specified by the manufacturer as suitable for the
intended purpose.

The floor around the machine must be level,
clean and free of loose particles, such as chips

and cutting residues.

– Do not remove any cutting residues or other

parts of workpieces from the cutting zone while

the machine is running and the saw unit is not

at rest.

– Make sure that the machine is always secured

on a workbench or a table if at all possible.

– Support long workpieces (e.g. with a roller table)

to prevent them sagging at the end of a cut.

Warning! This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions. In

order to prevent the risk of serious or deadly injuries, we

recommend that persons with medical implants consult

with their physician and the manufacturer of the medical

implant prior to operating the electric tool.

SAFETY INSTRUCTIONS FOR THE HANDLING OF

SAW BLADES
1
Only use insertion tools if you have mastered their

use.

2 Observe the maximum speed. The maximum

speed specified on the insertion tool may not be
exceeded. If specified, observe the speed range.

3 Observe the motor / saw blade direction of rota-

tion.

4 Do not use any insertion tools with cracks. Sort out

cracked insertion tools. Repairs are not permitted.

5 Clean grease, oil and water off of the clamping

surfaces.

6 Do not use any loose reducing rings or bushes for

the reducing of holes on saw blades.

7

Make sure that fixed reducer rings for securing the
insertion tool have the same diameter and have at

least 1/3 of the cutting diameter.

8

Make sure that fixed reducer rings are parallel to
each other.

9 Handle insertion tool with caution. They are ideally

stored in the originally package or special contain-

ers. Wear protective gloves in order to improve

grip and to further reduce the risk of injury.

10 Prior to the use of insertion tools, make sure that

all protective devices are properly fastened.

11 Prior to use, make sure that the insertion tool

meets the technical requirements of this electric

tool and is properly fastened.

12 Only use the supplied saw blade for cutting wood,

never for the processing of metals.

Attention: Laser radiation

Do not stare into the beam

Class 2 laser

Protect yourself and you environment from acci-

dents using suitable precautionary measures!
• Do not look directly into the laser beam with unpro-

tected eyes.

• Never look into the path of the beam.

Never point the laser beam towards reflecting sur-
faces and persons or animals. Even a laser beam

with a low output can cause damage to the eyes.

Caution - methods other than those specified here
can result in dangerous radiation exposure.

• Never open the laser module. Unexpected exposure

to the beam can occur.

• If the mitre saw is not used for an extended period

of time, the batteries should be removed.

• The laser may not be replaced with a different type

of laser.

• Repairs of the laser may only be carried out by the

laser manufacturer or an authorised representative.

Safety instructions for handling batteries
1

Always make sure that the batteries are inserted

with the correct polarity (+ and –), as indicated on

the battery.

2

Do not short-circuit batteries.

3

Do not charge non-rechargeable batteries.

4

Do not overcharge batteries!

5

Do not mix old and new batteries or batteries of

different types or manufacturers! Replace an entire

set of batteries at the same time.

6

Immediately remove used batteries from the de-

vice and dispose of them properly! Do not dispose

0