Preparation for transporting, Ordering spare parts, Disposal – Parkside PSE 2800 A1 User Manual
Page 21: Troubleshooting guide, Maintenance schedule
21
GB/MT
Cleaning, maintenance, storage, transport and ordering replacement parts
Cleaning ... / Disposal / Troubleshooting guide / Maintenance schedule
Change the oil after each season. To do this,
remove the old oil from the warm engine and
refill with new oil.
Remove the spark plug (fig. N / Pos. N1). Fill
about 20 ml of oil into the cylinder using an oil
can. Slowly pull the express start so that the oil
protects the cylinder from the inside. Screw the
spark plug back in.
Store the device in a well ventilated place or
area.
Preparation for transporting
Empty the petrol tank with a petrol suction pump
or alternatively using the petrol tap and a suita-
ble canister.
Once it it ready for use,
leave the engine running
until the rest of the petrol has been used up.
Empty the engine oil from the engine (as de-
scribed).
Remove the spark plug connector (Fig M) from
the spark plug.
Secure the device with a tension belt to prevent
it slipping out of place.
Ordering spare parts
When ordering replacement parts you should give
the following information:
Type of device
Device article number
Device ID number
Find current information at
www.kompernass.com
Disposal
The packaging is
made of environmentally friendly materi-
als. It can be disposed of at your local
recycling centre.
Do not dispose of
electric equipment in the household waste!
According to European Directive 2002 / 96 / EC,
used electrical devices must be collected and recy-
cled in an environmentally friendly manner.
Contact your local refuse disposal authority for more
details of how to dispose of your worn-out devices.
Troubleshooting guide
Fault
Cause
Remedy
Engine does
not start
Automatic oil
cut-out has not
responded
Check oil level,
top up engine oil
Spark plug
fouled
Clean or replace
spark plug
(electrode
spacing 0.6 mm)
No fuel
Refuel / have
the petrol cock
checked
Generator
has too little
or no voltage
Controller or
capacitor
defective
Contact your
dealer
Overcurrent
circuit-breaker
has triggered
Actuate the circuit-
breaker and reduce
the consumers
Air filter dirty
Clean or replace
the filter
Maintenance schedule
Please adhere to the following maintenance periods
in order to ensure a failure-free operation.
IMPORTANT! The equipment must be
filled with engine oil and fuel before it
is started.