Cleaning, maintenance, storage, transport and ordering replacement parts
We recommend that you clean the device after
every use.
Regularly clean the device with a damp cloth
and a little soft soap. Do not use any cleaning
products or solvents which could attack the plas-
tic part of the device. Ensure that no water can
penetrate the housing.
Air filter
Also refer to the service information.
Clean the air filter regularly, and if necessary
exchange it.
Open both brackets (fig. K / Pos. K1) and remove
the air filter lid (fig. K / Pos. K2).
Remove the filter element (fig L / Pos. L1).
When cleaning the element do not use any strong
cleaners or petrol.
Clean the element by tapping it on a flat surface.
If it is very dirty wash with soapy water, rinse
with clean water and leave to dry.
Put it back together in the opposite order.
Spark plug (fig. M–N)
Check the spark plug
28
after the first 20 hours of
use for dirt and if necessary clean it with a copper
wire brush. Then service the spark plug after every
50 hours of use.
Remove the spark plug connector
29
(fig. M)
with a turning movement.
Remove the spark plug
28
(fig. N / Pos. N1)
with the spark plug socket
26
included.
Put it back together in the opposite order.
Note: alternative spark plugs to F7RTC:
Bosch WR7DC
Petrol filter (Fig. A)
Note: The petrol filter
5
is a filter bowl located
directly under the petrol cap
2
, filtering any petrol
added.
Turn the ON /O FF switch
11
to the „OFF“
position.
Open the petrol cap
2
.
Remove the petrol filter
5
and clean in a non-
flammable solvent or solvent with a high tlash
point.
Reinsert petrol filter
5
.
Close the petrol cap
2
.
Changing the oil, checking the
oil level (before each use)
Changing the oil should take place when the engine
is warm.
Only use engine oil (15 W-40).
Put the generator on a suitable mat, slightly
tilted towards the oil drain plug
9
.
Open the oil fill plug
8
.
Open the oil drain plug and pour the warm
engine oil into a collection tank.
After pouring out the old engine oil, close the
oil drain plug and put the generator upright.
Pour in engine oil up to the top mark on the
dipstick (approx. 0.6 l).
ATTENTION! When checking the oil level
with the dipstick (oil fill plug) do not screw it
on, just plug it in until the threads.
The old oil must be disposed of according to
the regulations.
Low oil switch off
The low oil switch-off responds, if there is not enough
engine oil. In this case, the engine will not start or
switches off automatically after a short period of
operation. A restart will only be possible after top-
ping-up the oil level (see Chapter „Oil change,
checking the oil level (before every use)“).
Preparation for storage
Empty the petrol tank with a petrol suction pump.
Start the engine and leave it running until the
rest of the petrol has been used up.