Introduction / safety information introduction, Scope of delivery, Safety information – Parkside PESG 120 A1 User Manual
Page 7
7
GB
Introduction / Safety information
Introduction
devices must be collected separately
and taken for environmentally com-
patible recycling. Alternate recycling
option for return request:
The owner of the electrical equipment
is alternatively obligated to contrib-
ute to proper recycling in place of
a return in the case of abandonment.
For this purpose the used equipment
may also be taken to a collection
site disposing within the terms of the
German Closed Substance Cycle
and Waste Management Act. This
does not apply to accessories at-
tached to the used equipment and
implements without electrical com-
ponents.
Carefully read and follow the in-
structions for use before using this
equipment.
Do not store or use the equipment
in a wet environment or in the rain.
Only use the equipment in confined
spaces.
Electric shock from the welding
electrode can be fatal.
Inhaling welding fumes can
jeopardize your health.
Welding sparks can cause an
explosion or fire.
Arc rays can damage the eyes and
injure the skin.
Electromagnetic fields can interfere
with the functionality of pacemakers.
Electrode holder connection
Earth terminal connection
Mains connection:
230 V ~50 Hz
Max. welding current
and the respective
conventional load voltage: 30 A / 19.2 V-80 A /
21.2 V
U
0
:
48 V
I2max:
80 A
U1:
230 V
I1max:
18 A
I
1eff
:
7.1 A
Scope of delivery
1 Welding Equipment
1 Welding shield
2 Welding cables
1 Instructions for assembly and use
Safety information
Please carefully read the instructions for use and
follow the specified notices. Familiarise yourself with
the equipment, its proper use and the safety notices
using these instructions for use. The nameplate con-
tains all the technical data for this welding equipment,
please obtain information on the technical facts of
this equipment.
Only have repairs and / or maintenance
performed by electrically skilled persons.
Only use the welding cables included (PESG
120 A1 H01N2-D1x10 mm²).
During use the equipment should not be lo-
cated directly against a wall, be covered, or
be jammed between other equipment to ensure
ample air can be taken in through the ventila-
tion louvres. Verify the equipment is correctly
connected to the mains voltage. Avoid any ten-
sile load on the mains. Unplug the mains plug
from the socket before transferring the equip-
ment to a different location.
Always switch the equipment off with the ON /
OFF switch when not in use. Set the electrode
holder down on an insulated pad and allow to
cool for 15 minutes before removing the elec-
trodes from the holder.