Troubleshooting

Fault/possible cause

Remedy

No material fl ow

The air is not dry
enough.

Install a water separator
in your compressed air
system.

Air pressure too low

Increase the output
pressure of your com-
pressor.

Attachment not sitting
correctly

Ensure that the attach-
ment is fi rmly on the
appliance and that
no air escapes at the
sides.

Blocked sand-blasting
material pipes

Check that no lumps of
sandblasting material
are blocking the pipes.
Preferably use a
blow-off gun to clean
blocked pipes.
(Wear protective
glasses!) Also check
the outlet opening of
the tank.

Sand-blasting pattern not as expected

The air is not dry
enough.

Install a water separ-
ator in your com-
pressed air system.

Grain size of the sand-
blasting material not
uniform

Replace sand-blasting
material.

Sand-blasting material
impure

Clean/replace sand-
blasting material

The attachment is worn
out

Replace the attach-
ment

Other defects

Please contact an expert or your retailer.

Components

(see back fold-out page)

Item no.

Description

Amount

01

Housing

1

02

Screw

2

03

Screw

1

04

O-ring

1

05

Pin

1

06

Air valve spring

1

07

O-ring

1

08

Screw nut

1

09

Spring

1

10

Trigger

1

11

Air inlet

1

12

Socket

1

13

Nozzle

1

14

O-ring

2

15

Beaker ring

1

16

Connecting piece

1

17

Nozzle

1

18

Control lever

1

19

O-ring

1

20

Connection lever

1

21

Pin

1

22

Adjusting knob

1

23

Screw

1

24

Container

1

25

Screw nut

1

26

O-ring

1

27

Protective cover

1

28

Screw

1

29

Screw cap

1

30

Handle cover

1

31

Nozzle

1

32

Nozzle

1

IB_43089_PDSP1000B2_LB4.indb 6

IB_43089_PDSP1000B2_LB4.indb 6