beautypg.com

Parkside PSBS 240 B2 User Manual

Page 60

background image

60

GB

Change grinding disc

Information on replace-

ment:

• Never operate the device without

protective equipment.

• Ensure that the rotation speed

stated on the grinding disc (

19) is the same or higher than

the nominal rotation speed of the

device.

• Ensure that the grinding disc

dimensions match those of the

device.

• Only use flawless grinding discs

(ringing test: when you strike the

grinding disc with a plastic ham-

mer, it results in a clear sound).

• Never re-drill a locating hole

which is too small to make it

larger.

• Never use separate bushings or

adapters in order to make grind-

ing discs whose hole is too large

fit the device.

• Do not use any saw blades.

• To clamp the grinding tools only

use the clamping flange provid-

ed. The pads between the clamp-

ing flange and the grinding tools

must be made of elastic materials

e.g., rubber, soft cardboard etc.

• Always reassemble the device

completely after replacing the

grinding disc.

Switch the device off and remove

the mains plug.

Allow the device to cool down.

Wear protective gloves when

changing the grinding discs in or-

der to avoid cutting damages.

1. Remove the spark protection (

1) (see „Assemble/set spark pro-

tection).

2. Loosen the 3 fixing screws (15)

and remove the grinding disc

cover (16).

3. Loosen the fixing screws (11) and

remove the grinding belt cover

(12) (see „Changing the grinding

belt“).

4. Unscrew the grinding disc nut

(19a) in the clockwise direction,

by holding the nut of the opposite

roller of the grinding belt in place

(see small image).

5. Remove the clamping flange

(19b) and the grinding disc (19).

6. Set up the new grinding disc (19)

and the clamping flange and

manually screw the grinding disc

nut (19a) in the anti-clockwise

direction.

7. Screw the grinding disc cover

(16).

8. Set the spark protection (

1)

and the workpiece support (

18) so that the distance between

the grinding disc (19) is max.

2 mm (see „Assembly“).

The grinding disc nut must not be

screwed too tightly in order to

avoid a breaking of the grinding

disc and nut.

Test run:

Before starting work and after each

change of grinding disk, carry out a test

run of at least 60 seconds with no load.

Switch off the equipment immediately if the

disk runs lumpy, substantial vibrations oc-

cur, or abnormal noises are generated.