beautypg.com

Operation – Parkside PSBS 240 B2 User Manual

Page 58

background image

58

GB

Assemble/set work-

piece supports

1. Screw the workpiece supports

(6/18) on to the device.

2 positions (see

A + B) are

possible for the tape loop.

2. To do so, use the screws

(5a/17a), washers (5b/17b),

toothed lock washer (5c/17c)

and star grip nuts (5/17) pro-

vided.

3. Set the workpiece support of the

grinding belt (19) with the star

grip nut (17) so that the distance

between the grinding belt (19)

and the workpiece support is

max. 2 mm (see small image).

Periodically readjust the workpiece

support in order to offset the wear

and tear of the grinding disc (dis-

tance max. 2 mm).

Screw device on to work-

bench

Screw the device onto the work-

bench with 4 screws and nuts.

Insert the screws through the 4 bore

holes (13) on the base of the de-

vice.

The screws and nuts required for as-

sembly are not part of the scope of

delivery.

Operation

Caution! Risk of injury!

- Always disconnect the plug from

the mains socket before working.

- Use only grinding disks and acces-

sories recommended by the manu-

facturer. The use of other insertion

tools and other accessories may

cause risk of injury.

- Only use grinding tools which

bear information about the manu-

facturer, type of binding, dimen-

sion and permitted number of

revolutions.

- Only use grinding discs where

the printed rotational speed is at

least as high as what has been

specified on the name plate of

the device.

- Do not use broken, cracked or oth-

erwise damaged grinding disks.

- Never operate the device without

the visual protection disk.

- Always inspect the grinding disc

before starting the device:

Check the distance between the

spark protection and grinding

disc as well as workpiece support

and grinding disc (distance maxi-

mum 2 mm).

- The grinding disc must be re-

placed once the spark protection

and workpiece support on the

grinding disc do not have dis-

tance of max. 2 mm.

- Switch on the equipment only

when it is safely installed on the

work surface.

Keep your hands away from

the grinding disc and grind-

ing belt when the device is in

operation. Injury hazard!