beautypg.com

Enerco HSVFR30LPT User Manual

Page 12

background image

12

Installation Instructions and Owner’s Manual

Unvented LP-Gas Vent Free Room Heaters

A yellow tip on the pilot flame indicates dust and dirt in

the pilot assembly. To clean the pilot assembly find the

small pilot air inlet hole about two inches from where

the pilot flame comes out of the pilot assembly (see

figure 25). With the unit off, lightly blow air through the

air inlet hole. You may blow through a drinking straw if

compressed air is not available.

Figure 25

CLEANING HEATER CABINET

Air passageways

Use a vacuum cleaner or pressurized air to

clean

Exterior

Use a soft cloth dampened with a mild soap

and water mixture. Wipe the cabinet to remove

dust.

WARNING: Failure to keep the primary air

opening(s) of the burner(s) clean may result in soot-

ing and property damage.

CLEANING ODS/PILOT AND BURNER

Use as vacuum cleaner, pressurized air or

small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit ever 2,500

hours of operation or every three months. We also

recommend that you keep the burner tube and pilot

assembly clean and free of dust and dirt. To clean these

parts we recommend using compressed air no greater

than 30 psig.
This can be done by using a vacuum cleaner in the

blow position, using compressed air in a can, please

follow the directions on the can. If you don’t follow

directions on the can you could damage the burner or

pilot assembly. In addition, the directions that follow

should also be followed.

1. Shut off the unit, including the pilot. Allow the

unit to cool for at least thirty minutes.

2. Inspect burner and pilot for dust and dirt.
3. Blow air through the port/slots and holes in the

burner.

Figure 17

Note: Your heater may have either pilot assembly.

Figure 21

Correct pilot position.

Figure 22

Incorrect pilot position.

Pilot Air Inlet Hole

Pilot Assembly