beautypg.com

Gb trouble shooting – Parkside PHD 150 C2 User Manual

Page 15

background image

15

GB

Trouble shooting

Problem

Possible cause

Remedy

Severe pres-

sure fluctua-

tions

Standard Vario nozzle (18)

is soiled

Rinse the standard Vario nozzle (18)

with water. If required, clean the nozzle

bore hole with a needle (see chapter en-

titled cleaning).

Standard Vario nozzle (18)

is blocked

Remove the nozzles (17/18) or the wash

brush (19) and ensure that the water can

discharge from the jet gun (1) unimped-

ed. In other words, the device is working

perfectly. The turbo dirt blaster (17) and

the rotating wash brush (18) do not nor-

mally get blocked.

Pressure

cleaner is not

operating

ON / OFF switch (10) is

turned off

Check ON / OFF switch (10)

Damaged power supply

cable (6)

Switch off the equipment and disconnect

from the mains. Check power supply

cable (6) for damage. If necessary have

the power supply cable (6) replaced by

a qualified electrician.

Mains fault

Check the electrical system for conform-

ity with the data on the rating plate.

Pressure clean-

er does not

generate any

pressure

Air trapped in the pressure

cleaner

Switch on the equipment with the jet gun

and with no nozzle until bubble-free wa-

ter comes out.

Drop in the water mains

pressure

Check the water mains.

Leaks in the

water system

Connections not fitted cor-

rectly

Switch off the equipment and disconnect

from the mains. Reconnect the equipment

to the water pipes (cf. “Initial Operation/

Set-Up”)

Water connection (9) leaks

Switch off the equipment and disconnect

from the mains. Replace the water con-

nection (9) inc. gasket (cf. “Spare Parts”)

This manual is related to the following products: