1. Remove the rear cover, the GND cable, and the two 2P connectors.
2. Connect the coaxial cable and the power cable.
After connecting the power cable on the terminal block, be sure to mount the protective cover.
Caution:
Fasten the weatherproof cap firmly, and make sure that the cable is fixed
completely. If the cap is not fastened firmly, water leak may be caused.
(The appropriate tightening torque: 4.0~4.5N.m)
When connecting the coaxial cable, be sure to remove the 2P connectors.
3. Connect the two 2P connectors and the GND cable.
After connecting the connectors and the cable, mount the rear cover.
Caution:
The rear cover has a weatherproof seal. Before mounting the rear cover, make
sure that the seal is set in the groove in the rear cover. If the setting of the seal is
not sufficient, water leak may be caused.
When mounting the rear cover, be careful not to pinch the two 2P connectors or
the GND cable.
Be sure to connect the ground wire of the power cable to the earth terminal
.
Do not use the power cable of flat type, which does not fit
the weatherproof cap.
For the power cable, use one attached with a force-fit
terminal.
If the force-fit portion of the force-fit terminal is protruded
from the terminal block, insulate the force-fit portion.
Coaxial cable clamp
Weatherproof cap
Coaxial cable
Rear cover
Seal
GND cable
Terminal block
(with protective cover)