beautypg.com

How to order liebert accuguide – Emerson AccuGuide ACGY1110808 User Manual

Page 2

background image

While every precaution has been taken to ensure accuracy and

completeness in this literature, Liebert Corporation assumes no

responsibility, and disclaims all liability for damages resulting

from use of this information or for any errors or omissions.

© 2006 Liebert Corporation. All rights reserved throughout

the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks

of their respective owners.

® Liebert and the Liebert logo are registered trademarks

of the Liebert Corporation.

SL-22070 (R10/06) Printed in USA

Business-Critical Continuity, Emerson Network

Power and the Emerson Network Power logo

are trademarks and service marks of Emerson

Electric Co. ©2006 Emerson Electric Co.

Emerson Network Power.com

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity

.

AC Power

Connectivity

DC Power

Embedded Computing

Embedded Power

Monitoring

Outside Plant

Power Switching & Controls

Precision Cooling

Racks & Integrated Cabinets

Services

Surge Protection

Liebert Corporation

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. &

Canada Only)

614 888 0246 Phone (Outside U.S.)

614 841 6022 FAX

Via Leonardo Da Vinci 8

Zona Industriale Tognana

35028 Piove Di Sacco (PD)

Italy

39 049 9719 111 Phone

39 049 5841 257 FAX

Emerson Network Power Asia Pacific

7/F., Dah Sing Financial Centre

108 Gloucester Rd, Wanchai

Hong Kong

852 25722201 Phone

852 28029250 FAX

liebert.com

Technical Support

800 288 6169 Toll-Free

607 724 2484 Phone

607 722 8713 Fax

How To Order

Liebert AccuGuide

®

Voltage configuration:

Wye (Y), Delta (D), Split Phase (S)

Modes of protection:

111-All modes for Y system

110-line to line, line to ground

101-line to neutral, neutral to ground

Liebert AccuGuide lengths:

5 feet 8 feet 10 feet 12 feet 15 feet 20 feet

Pigtail gauge:

No. 6 AWG No. 8 AWG No. 10 AWG

Note: 5 feet of pigtail length will be provided on each
side of the Liebert AccuGuide assembly. Please specify
pigtail gauge (conduit nipple to SPD connection/conduit
nipple to power source connection).

How to construct an AccuGuide

(ACG) model #

Code

1. Liebert AccuGuide

ACG

2. Voltage configuration

Y

3. Mode of protection

111

4. Liebert AccuGuide length: 8 feet

08

5. Pigtail gauge: No. 8 AWG

08

Sample model #: ACGY1110808

Required conduit size: 1 ⁄2" to 2"

Liebert AccuGuide Coax Construction

Ordering Information:

Liebert AccuGuide cable assemblies are available

in several standard lengths for any service

configuration with up to seven modes of

protection. The conductor gauge is configured

to accommodate the system.

Primary &
Secondary
Insulation

Jacket

Outer Braid

Inner Braid

Conductor

General Specifications

Voltage (VAC)

0 to 600

Operating frequency (Hz)

0 to 400

Altitude (m)

18,000 feet

Operating temperature (°C)

-40 to +90

Operating humidity (%)

0 to 95 (non-condensing)

Flame resistance

VW-1

DC resistance (mΩ/ft/mode) ≤ 1.3

Warranty

5-years

Safety agency approval

UL Listed Wire Assembly Kit

Patent number

5,384,429