beautypg.com

Setup, 0 adjusting the me-sbc, B attery v oltage – Magnum Energy Smart Battery Combiner (ME-SBC) User Manual

Page 14

background image

11

©2009 Magnum Energy Inc.

Setup

3.0 Adjusting the ME-SBC

TM

The above diagram represents a typical three-stage charging profi le. The fi rst

of the three stages is Bulk Charge. This is where up to 80% of the charging

is accomplished. During this stage the battery voltage increases signifi cantly

and the current that the charging source is providing to the Main Battery

is at a maximum. The second stage is Absorption, during this stage the bat-

tery voltage is held at the Absorption voltage for a period of time. By the end

of this process the charge on the battery bank is about 95% complete. The

third and fi nal stage is Float. In this stage, the remainder of the charging

is accomplished. As long as the Main Battery voltage is between the Low

Voltage Disconnect and the High Voltage Disconnect, and the Main bat-

tery voltage is above the Connect Voltage, the ME-SBC

TM

will pass charging

current through to the Auxiliary Battery.

The ME-SBC

TM

combining setpoints as follows:

Connect Voltage: (Settable: 12.8-13.8 VDC) adjusts the point at which the ME-

SBC

TM

passes the charge from the Main Battery bank to the Auxiliary Battery bank

or vice versa. This setting is not active until a charging source is applied to one of the

batteries and the voltage begins to increase. Once this setpoint has been reached, the

ME-SBC

TM

will automatically start to pass the charge current through to the other bat-

tery. Default = 12.8 / 25.6 VDC (12V /24 V system)

Low Voltage Disconnect: (Settable: 12.5-13.5 VDC) once the charging process has

begun and the battery voltage has exceeded the Connect Voltage setpoint, the Low

Voltage Disconnect becomes active. If the voltage begins to decrease, this is the

point at which the ME-SBC

TM

disconnects and stops passing charge current through to

the other battery. Default = 12.5 / 25.0 VDC (12V /24 V system)

High Voltage Disconnect: (Settable: 14.0-15.0 VDC) This setting should be used to

prevent the ME-SBC

TM

from passing through too high of a voltage from one battery to

other. If this voltage is reached, the ME-SBC

TM

disconnects the batteries and prevents

the high voltage from affecting the other battery. Default = 14.0 / 28.0 VDC (12V /24

V system)

Figure 3-1, Battery combining setpoints

H igh V oltage

D is c onnec t

C onnec t V oltage

D is c onnec t

Low V oltage

D is c onnec t

A bs orption Float

B attery V oltage

- C onnec ted

B ulk