Ion Science GasCheck IS User Manual
Page 4
GASCHECK 3000 & 3000IS MANUAL
Ion Science Ltd
Page 4 of 28
Unrivalled Detection. www.ionscience.com
Declaration of conformity
GasCheck 3000IS
Manufacturer: Ion Science Ltd, The Way, Fowlmere, Cambridge, England. SG8 7UJ
Product: GasCheck 3000is (Black Case) (intrinsic version only)
Product description: an intrinsically safe handheld micro thermal conductivity sensor designed
specifically for use in potentially explosive atmospheres and for the search and location of flammable
gas leaks.
Marking:
ll 2 G Ex ia IIC T4 (-20°C ≤ Ta ≤ +60°C)
Certificate Number Baseefa 02ATEX0093
Notified body: ATEX: Baseefa 2001 Ltd, Rockhead Business Park, Staden Lane, Buxton, Derbyshire, SK17
9RZ
Notified body No: EC1180
Directives: 94/9/EC
ATEX 100A
89/336/EC EMC
Standards: BS EN 13908:2002
ATEX – Application of quality systems
BS EN 50014:1998
ATEX – general requirements
BS EN 50020:2002
ATEX – Intrinsic safety “i”
BS EN 61010-1:2001
Safety requirements for measurement, control & lab equipment
BS EN ISO 9001:2008
Quality management systems
BS EN61326-1:1997
EMC – Equipment for measurement, control and laboratory use
Signed By:
Name: Mark Stockdale,
Position: Technical Director
Date: 23
rd
April 2007
Safety Rating: This intrinsic safety rating permits its deployment in all potentially explosive
atmospheres of the quoted (or less demanding) rating. That is, in areas where explosive gases (of
Group IIA, IIB and IIC) are intermittently present (Zone 1), within an ambient temperature range of -
20°C and +60°C.
GasCheck complies with the requirements of 73/23 EEC low voltage directive and, apart from a low
voltage pump, there are no moving parts within the instrument so that the machinery directives are not
applicable.