Table 5 240 V Single-Phase Input (-5% to +10%), 208 V Three-Phase Motor

Table 6 480 V Single Phase Input (-5% to +10%), 460 V Three Phase Motor

Drive Model

Without Additional Impedance

With Additional Impedance (use either DC type or AC type)

Output Capacity

Single Phase Input Load

Yaskawa Reactor Part Number

Output Capacity

Single Phase Input Load

Motor Power

(HP)

Motor FLA Power (kVA) Current (A)

DC Type

AC Type

Motor Power

(HP)

Motor FLA Power (kVA) Current (A)

2A0004

0.33

1.7

0.99

4.3

URX000043

URX000303

0.5

2.4

0.94

4.1

2A0006

0.5

2.4

1.3

5.7

URX000043

URX000303

0.75

3.5

1.3

5.7

2A0008

0.75

3.5

1.7

7.7

05P00620-0113

URX000307

1

4.6

1.6

7.2

2A0010

0.75

3.5

1.8

7.7

05P00620-0113

URX000311

1

4.6

1.8

7.8

2A0012

1

4.6

2.3

10

05P00620-0115

URX000315

2

7.5

2.9

13

2A0018

2

7.5

4.3

19

05P00620-0120

URX000319

3

10.6

4.3

19

2A0021

2

7.5

4.3

19

05P00620-0120

URX000323

3

10.6

4.4

19

2A0030

2

7.5

4.5

20

05P00620-0120

URX000323

3

10.6

4.4

19

2A0040

3

10.6

6.2

27

05P00620-0124

URX000323

5

17

6.7

30

2A0056

5

17

9.9

43

URX000059

URX000326

7.5

24

9.6

42

2A0069

5

17

10

45

URX000063

URX000332

10

31

13

56

2A0081

10

31

18

79

URX000072

URX000339

15

46

19

84

2A0110

10

31

14

60

DC Reactor

Built-in

URX000340

15

46

17

76

2A0138

15

46

20

87

URX000343

15

46

18

77

2A0169

20

59

26

114

URX000342

20

59

23

102

2A0211

20

59

26

116

URX000344

25

75

29

129

2A0250

25

75

32

143

URX000347

30

88

35

156

2A0312

30

88

39

170

URX000350

40

114

47

204

2A0360

40

114

51

224

URX000353

50

143

57

252

2A0415

50

143

63

275

URX000356

60

169

69

301

Drive Model

Without Additional Impedance

With Additional Impedance (use either DC type or AC type)

Output Capacity

Single Phase Input Load

Yaskawa Reactor Part Number

Output Capacity

Single Phase Input Load

Motor Power

(HP)

Motor FLA Power (kVA) Current (A)

DC Type

AC Type

Motor Power

(HP)

Motor FLA Power (kVA) Current (A)

4A0002

0.33

0.76

1.1

2.4

URX000041

URX000295

0.5

1.1

0.98

2.1

4A0004

0.75

1.6

1.9

4.2

URX000041

URX000299

1

2.1

1.7

3.8

4A0005

1

2.1

2.3

5.1

05P00620-0110

URX000303

1.5

3

2.5

5.5

4A0007

1

2.1

2.5

5.6

05P00652-0213

URX000308

2

3.4

3

6.7

4A0009

2

3.4

4.6

10

URX000048

URX000312

3

4.8

4.3

9.5

4A0011

2

3.4

4.6

10

URX000053

URX000316

3

4.8

4.7

10

4A0018

2

3.4

4.4

9.7

URX000052

URX000316

3

4.8

4.6

10

4A0023

3

4.8

6.3

14

URX000052

URX000316

5

7.6

7

15

4A0031

5

7.6

10

22

URX000055

URX000324

7.5

11

9.9

22

4A0038

7.5

11

14

31

05P00620-0123

URX000327

10

14

14

31

4A0044

7.5

11

14

31

URX000061

URX000327

10

14

13

28

4A0058

10

14

14

30

DC Reactor

Built-in

URX000332

15

21

19

41

4A0072

15

21

20

43

Do Not Use
AC Reactor

15

21

20

43

4A0088

15

21

20

44

15

21

20

44

4A0103

15

21

20

45

URX000335

20

27

25

54

4A0139

30

40

38

84

URX000341

30

40

36

80

4A0165

30

40

39

85

URX000341

30

40

37

81

4A0208

50

65

62

136

URX000347

50

65

59

130

4A0250

60

77

74

162

URX000347

60

77

70

154

4A0296

60

77

75

165

URX000350

75

96

87

192

4A0362

75

96

93

205

URX000353

100

124

115

251

4A0414

100

124

122

267

URX000356

125

156

143

314

4A0515

100

124

125

275

URX000353

100

124

116

255

4A0675

125

156

157

345

Do Not Use

125

156

157

345

This manual is related to the following products: