2 Product Overview

2

Product Overview

About This Product

The DI-100 option has seven optically isolated input terminals which can be used to connect

external 120 Vac control circuitry to the V1000 drive. The DI-100 Option mounts directly to

the V1000 control board terminals (S1 ~ S7 and SC). This option makes it possible to

control the V1000 digital inputs with 120 Vac.
This manual explains the handling, installation and specifications of this product.

Note: With this option is installed, safety input terminals H1 and HC on the V1000 drive are designed

to the functionality but are not certified to EN61800-5-1, EN954-1/ISO13849 Category 3, IEC/

EN61508 SIL2, Insulation cooridination: Class 1.

Applicable Models

This option can be used with the drive models in

Table 1

.

Table 1 Applicable Models

Drive Models

Model Notes

CIMR-VUBA0001

~BA0003

CIMR-VU2A0001

~2A0006

1-phase 200 V

and 3-phase 200 V

(small frame)

<1>

<1> Because the bottom cover/conduit bracket is discarded for DI-100 installation, the enclosure rating of these

models becomes IP00 or NEMA Open Type after DI-100 option installation.

CIMR-VUBA0006

thru BA0018

CIMR-VU2A0010

thru 2A0020

CIMR-VU4A0001

thru 4A0011

1- phase 200 V

3-phase 200/400 V

(medium frame)

<1>

CIMR-VU2A0030

thru CIMR-VU2A0069

CIMR-VU4A0018

thru CIMR-VU4A0038

3-phase 200/400 V

(large frame)