6
the alphanumeric display. The XY
coordinate system used is as follows:
KEYPAD, FRONT VIEW
X =
0
1
2
3
4
|
|
|
|
|
Y = 0 —
00 10 20 30 40
1 —
01 11 21 31 41
2 —
02 12 22 32 42
3 —
03 13 23 33 43
PB1 ("NAME" push button) = 99
PB2 ("NEXT" push button) = 98
ERROR MESSAGES
When the RDU detects an error
condition, it shows an error message in the
alphanumeric display. The RDU reactions
and the error condition that caused the
reaction are as follows:
RDU REACTION
ERROR CONDITION
Shows “COMM.
35 seconds have
FAILURE” on alpha- elapsed since RDU
numeric display
has been updated
and blanks the
from RDC
numeric display
Shows “ - ” for the
Received invalid
number
numeric value
Bottom segment
Received invalid
of most significant
numeric value
digit is lit
Shows “ERR - WD
Watchdog timed out
TIMEOUT” and
halts
RDU REACTION
ERROR CONDITION
Shows “ERR - INT
Timer overflow inter-
TIMER” and halts
rupt occurred and
should not have
Shows “ERR - INT
A/D interrupt
A/D” and halts
occurred and should
not have
Shows “ERR - INT
HSI interrupt
HSI” and halts
occurred and should
not have
Shows “ERR - INT
HSO interrupt
HSO” and halts
occurred and should
not have
Shows “ERR - INT
HSI.0 interrupt
HSI.0” and halts
occurred and should
not have
Shows “ERR - INT
External interrupt
EXT” and halts
occurred and should
not have
RD 791-10